User manuals:

Walli Roller Shutter
FGWREU-111

Downloads
Declarations
Declaration of conformity:
Description and features
Description
FIBARO Walli Roller Shutter is a smart wall switch designed to control motors of roller blinds, awnings, venetian blinds and other single phase, AC powered devices via Z-Wave network.
It measures active power and energy consumed by the controlled load.
You can install it with provided cover plate and switch button or other compatible.
Main features
- Can be used with:
- roller blinds ,
- venetian blinds,
- awnings,
- blind motors with electronic or mechanical limit switches.
- Can be used with FIBARO Walli covers or other compatible:
- GIRA – System 55 (Standard 55, E2, Event, Event Clear),
- Legrand – Céliane,
- Schneider – Odace.
- Active power and energy metering.
- Supports Z-Wave network Security Modes: S0 with AES-128 encryption and S2 Authenticated with PRNG-based encryption.
- Works as a Z-Wave signal repeater (all non-battery operated devices within the network will act as repeaters to increase reliability of the network).
- May be used with all devices certified with the Z-Wave Plus certificate and should be compatible with such devices produced by other manufacturers.
The device is a Security Enabled Z-Wave Plus product and a Security Enabled Z-Wave Controller must be used in order to fully utilize the product.
Specifications
Power supply | 110-230V~ 50/60 Hz |
Rated load current | 4A for motors with compensated power factor (inductive loads) 13A for resistive loads |
Compatible load types | single-phase AC motors |
resistive loads | |
Required limit switches | electronic or mechanic |
Recommended external overcurrent protection | 10A type B circuit breaker (EU) 13A type B circuit breaker (Sweden) |
For installation in boxes | Ø = 60mm, depth ≥ 40mm |
Recommended wires | cross-section area between 1.5-4.0mm2, stripped 11.5-13mm of insulation |
Operating temperature | 0–35°C |
Ambient humidity | 10–95% RH without condensation |
Radio protocol | Z-Wave (500 series chip) |
Radio frequency band | 868.0–868.6MHz; 869.7–870.0MHz |
Max. transmitting power | +6dBm |
Range | up to 50m outdoors up to 40m indoors (depending on terrain and building structure) |
Dimensions (Height x Width x Depth) |
86 x 86 x 51 mm |
Compliance with EU directives | RoHS 2011/65/EU RED 2014/53/EU |
Radio frequency of individual device must be same as your Z-Wave controller. Check information on the box or consult your dealer if you are not sure.
Important safety information
Read this manual before attempting to install the device!
Failure to observe recommendations included in this manual may be dangerous or cause a violation of the law. The manufacturer, Fibar Group S.A. will not be held responsible for any loss or damage resulting from not following the instructions of operating manual.
- DANGER OF ELECTROCUTION!
- The device is designed to operate in electrical home installation. Faulty connection or use may result in fire or electric shock.
- All works on the device may be performed only by a qualified and licensed electrician. Observe national regulations.
- Even when the device is turned off, voltage may be present at its terminals. Any maintenance introducing changes into the configuration of connections or the load must be always performed with disabled fuse.
- To avoid risk of electrical shock, do not operate the device with wet or moist hands.
- Do not modify!
Do not modify this device in any way not included in this manual. - Other devices
The manufacturer, Fibar Group S.A. will not be held responsible for any damage or loss of warranty privileges for other connected devices if the connection is not compliant with their manuals. - This product is intended for indoor use only in dry locations.
Do not use in damp or wet locations, near a bathtub, sink, shower, swimming pool, or anywhere else where water or moisture are present. - Caution!
It is not recommended to operate all of the roller blinds simultaneously. For safety reasons, at least one roller blind should be controlled independently, providing safe escape route in case of emergency.
- Not a toy!
This product is not a toy. Keep away from children and animals!
Installation
Before installation
Connecting the device in a manner inconsistent with this manual may cause risk to health, life or material damage.
- Do not power the device before fully assembling it in the mounting box,
- Connect only in accordance with one of the diagrams,
- Install only in flush mounting boxes compliant with a relevant national safety standards and with depth no less than 40mm,
- Do not connect devices which are not compliant with the specification or relevant safety standards,
- Do not connect heating devices,
- Do not connect SELV or PELV circuits.
- Make sure you have all required parts when installing with covers other than FIBARO.
Device parts:
1 – switch button, 2 – cover plate, 3 – unit (device), 4 – mounting frame
Notes for diagrams:
N – terminal for neutral wire
Q1 – 1st output terminal motor
Q2 – 2nd output terminal motor
L – terminal for live wire
G – groove used to measure wire length
Preparing for installation
Prepare wires by removing 11.5-13mm of insulation from their ends. You can use groove on the side of the unit to measure the length.
When installing with FIBARO or GIRA covers:
- Pull out the switch button.
- Take off the cover plate.
When installing with Legrand or Schneider covers:
- Pull out the original switch button.
- Take off the original cover plate.
- Dismount the original mounting frame.
- Snap the new mounting frame*.
* Additional mounting frames are sold separately.
Electrical connection
- Switch off the mains voltage (disable the fuse).
- Connect with the diagram:
Diagram 1: Example connection with roller blind motor
- Verify correctness of connection.
- Tighten the terminal screws using PH1 screwdriver.
Assembling the device
When installing the device in the mounting box orient the device with terminal screws going up or to the left (for horizontal button position) to ensure button order.
The light effect might look different for covers other than FIBARO Walli. You can adjust colour and/or intensity of the LEDs to suit the particular cover (using parameters 11, 12, and 13) or disable it by changing parameter 13 to 0.
When installing with FIBARO covers:
If you have unit only: buy Switch Button with Lightguide (FG-WDSEU221-AS-8100) and Mounting Frame FIBARO/GIRA (FG-Wx-AS-4001).
- Insert the device with mounting frame into the mounting box and secure with mounting claws and screws.
- Snap the cover plate to the device.
- Snap the switch button to the device.
When installing with GIRA covers:
- Insert the device with mounting frame into the mounting box and secure with mounting claws and screws.
- Snap the new cover plate to the device.
- Snap the switch button adapter* to the device.
- Snap the new switch button to the device.
When installing with Legrand covers:
- Insert the device with mounting frame* into the mounting box and secure with mounting claws and screws.
- Snap the switch button adapter* to the device.
- Snap the new inner cover plate to the device.
- Snap the new outer cover plate to the device.
- Snap the new switch button to the device.
When installing with Schneider covers:
- Insert the device with mounting frame* into the mounting box and secure with mounting claws and screws.
- Snap the new cover plate to the device.
- Snap the new switch button to the device.
When installing with FIBARO double and triple covers:
Switch buttons, lightguides and mounting frames are necessary to install double and triple cover plates.
- If you have complete FGWREU-111: push the lightguide out through the single Cover Plate and use included switch button and mounting frame.
- If you have unit only: buy Switch Button with Lightguide (FG-WDSEU221-AS-8100) and Mounting Frame FIBARO/GIRA (FG-Wx-AS-4001) for every unit.
- Press in the lightguides into the cover plate (plastic latches should align).
- Insert the units with mounting frames into the mounting boxes and secure them with mounting claws and screws.
- Snap the cover plate.
- Snap the switch buttons.
* Switch button adapter and additional mounting frames are sold separately.
Activating the device
- If the device fully assembled, switch on the mains voltage.
- LED ring light means the device is powered and can be added to the Z-Wave network.
Parts compatibility
Available FIBARO parts |
Included in FGWREU-111 |
|
Name |
Symbol |
|
Walli Roller Shutter Unit |
FG-WREU111-AS-8001 |
x |
Switch Button with Lightguide |
FG-WDSEU221-AS-8100 |
x |
Switch Button Adapter |
FG-WDSEU221-PP-0007 |
|
Mounting Frame FIBARO |
FG-Wx-AS-4004 |
x |
Mounting Frame Gira |
FG-Wx-AS-4001 |
|
Mounting Frame Legrand |
FG-Wx-AS-4002 |
|
Mounting Frame Schneider |
FG-Wx-AS-4003 |
|
Single Cover Plate |
FG-Wx-PP-0001 |
x |
Double Cover Plate |
FG-Wx-PP-0003 |
|
Triple Cover Plate |
FG-Wx-PP-0004 |
Parts required for Gira System 55 (only with non-metalised outer surface: Standard 55, E2, Event, Event Clear) covers
Required FIBARO parts |
|
Name |
Symbol |
Walli Roller Shutter Unit |
FG-WREU111-AS-8001 |
Switch Button Adapter |
FG-WDSEU221-PP-0007 |
Mounting Frame Gira |
FG-Wx-AS-4001 |
Parts required for Legrand Céliane covers
Required FIBARO parts |
|
Name |
Symbol |
Walli Roller Shutter Unit |
FG-WREU111-AS-8001 |
Switch Button Adapter |
FG-WDSEU221-PP-0007 |
Mounting Frame Legrand |
FG-Wx-AS-4002 |
Compatible Legrand parts | |
Cover plates | 0 666 41, 0 666 31, 0 666 32, 0 691 31, 0 693 51, 0 691 11, 0 694 71, 0 689 21, 0 687 11, 0 691 21 |
Button | 0 680 01, 0 650 04 |
Parts required for Schneider Odace covers
Required FIBARO parts |
|
Name |
Symbol |
Walli Roller Shutter Unit |
FG-WREU111-AS-8001 |
Mounting Frame Schneider |
FG-Wx-AS-4003 |
Compatible Schneider parts | |
Cover plates | S52P702, S53P802J, S52P802R, S52P802J, S52P802L, S52P802M, S52P802U, S53P802P, S53P802V, S53P802, S52P802, S52P902W, S5X0802X (QP-2018-W17), S520802X, S5X0802X (QP-2018-W16), S5X0802X (QP-2017-W02), S520704X, S52P704A1, S52P704B1, S54P704, S52P704H, S52P704E, S52P704G, S52P704D, S52P704C |
Button | S52D201, S53D201 |
Z-Wave network
Adding to Z-Wave network
Adding (Inclusion) – Z-Wave device learning mode, allowing to add the device to existing Z-Wave network.
Adding manually
To add the device to the Z-Wave network manually:
- Power the device.
- Set the main controller into the adding mode (see the controller’s manual).
- Quickly, three times click one of the buttons.
- If you are adding in Security S2 Authenticated, input the underlined part of the DSK (label on the bottom of the box).
- LED will start blinking yellow, wait for the adding process to end.
- Adding result will be confirmed by the Z-Wave controller’s message and the LED frame:
- Green – successful (non-secure, S0, S2 non-authenticated),
- Magenta – successful (Security S2 Authenticated),
- Red – not successful.
- Power the device.
- Log into Home Center configuration interface.
- In Devices section click Add or remove device.
- Click Add to start adding mode.
- Quickly, three times click one of the buttons.
- If you are adding in Security S2 Authenticated, input the underlined part of the DSK (label on the bottom of the box).
- LED will start blinking yellow, wait for the adding process to end.
- Adding result will be confirmed by the Z-Wave controller’s message and the LED frame:
- Green – successful (non-secure, S0, S2 non-authenticated),
- Magenta – successful (Security S2 Authenticated),
- Red – not successful.
- Power the device.
- Click the Plus (+) icon on the Home Screen.
- Select FIBARO and click on the device.
- Choose a hub you want to add your device to and click Next.
- Choose a room where the device will be placed and click Next.
- Quickly, three times click one of the buttons.
- If you are adding in Security S2 Authenticated, input the underlined part of the DSK (label on the bottom of the box).
- LED will start blinking yellow, wait for the adding process to end.
- Adding result will be confirmed by the Z-Wave controller’s message and the LED frame:
- Green – successful (non-secure, S0, S2 non-authenticated),
- Magenta – successful (Security S2 Authenticated),
- Red – not successful.
- Power the device.
- From your Vera's Dashboard, go to Devices > Add devices
- Choose a Generic Z-Wave device from the list.
- Follow the instructions on screen.
- Quickly, three times click one of the buttons.
- If you are adding in Security S2 Authenticated, input the underlined part of the DSK (label on the bottom of the box).
- LED will start blinking yellow, wait for the adding process to end.
- Adding result will be confirmed by the Z-Wave controller’s message and the LED frame:
- Green – successful (non-secure, S0, S2 non-authenticated),
- Magenta – successful (Security S2 Authenticated),
- Red – not successful.
Click here for more detailed instructions for Vera gateways.
- Power the device.
- In Homey app select Devices from the tab bar.
- Find your device's brand and click the [+] icon in the top right corner and search for FIBARO and tap the logo.
- Find your device on the list. Then click the device's icon. A dialog will appear that confirms if you want to continue. Click install.
- Follow the on-screen instructions.
- Quickly, three times click one of the buttons.
- If you are adding in Security S2 Authenticated, input the underlined part of the DSK (label on the bottom of the box).
- LED will start blinking yellow, wait for the adding process to end.
- Adding result will be confirmed by the Z-Wave controller’s message and the LED frame:
- Green – successful (non-secure, S0, S2 non-authenticated),
- Magenta – successful (Security S2 Authenticated),
- Red – not successful.
Adding using SmartStart
SmartStart enabled products can be added into a Z-Wave network by scanning the Z-Wave QR Code present on the product with a controller providing SmartStart inclusion. SmartStart product will be added automatically within 10 minutes of being switched on in the network range.
To add the device to the Z-Wave network using SmartStart:
- To use SmartStart your controller needs to support Security S2 (see the controller’s manual).
- Enter the full DSK string code to your controller. If your controller is capable of QR scanning, scan the QR code placed on the label on the bottom of the box.
- Power the device.
- Wait for the adding process to start (up to few minutes), which is signalled with yellow LED blinking.
- Adding result will be confirmed by the Z-Wave controller’s message and the LED frame:
- Green – successful (non-secure, S0, S2 non-authenticated),
- Magenta – successful (Security S2 Authenticated),
- Red – not successful.
In case of problems with adding the device, please reset the device and repeat the adding procedure.
Removing from Z-Wave network
Removing (Exclusion) – Z-Wave device learning mode, allowing to remove the device from existing Z-Wave network. Removing also results in resetting the device to factory defaults.
To remove the device from the Z-Wave network:
- Power the device.
- Set the main controller in remove mode (see the controller's manual).
- Quickly, three times click one of the buttons.
- LED will start blinking yellow, wait for the removing process to end.
- Successful removing will be confirmed by the Z-Wave controller’s message and red LED colour.
- Power the device.
- Log into Home Center configuration interface.
- In Devices section click Add or remove device.
- Click Delete to start removing mode.
- Quickly, three times click one of the buttons.
- LED will start blinking yellow, wait for the removing process to end.
- Successful removing will be confirmed by the Z-Wave controller’s message and red LED colour.
- Power the device.
- On the Home Screen, select Menu icon and click Devices.
- Select More Options (three dots) icon and click Edit.
- Select the minus icon (-) next to the device.
- Click Delete to confirm.
- Quickly, three times click one of the buttons.
- LED will start blinking yellow, wait for the removing process to end.
- Successful removing will be confirmed by the Z-Wave controller’s message and red LED colour.
- Power the device.
- From your Vera's Dashboard, go to Devices.
- Choose the device you want to remove and click the arrow next to it.
- Go to the bottom of the page and click Delete Device.
- Click Unpair.
- Quickly, three times click one of the buttons.
- LED will start blinking yellow, wait for the removing process to end.
- Successful removing will be confirmed by the Z-Wave controller’s message and red LED colour.
- Power the device.
- In Homey app select Devices from the tab bar.
- Click and hold the device you want to remove.
- Click in the gear icon in the top right corner.
- Click Remove device.
- Confirm that you want to remove this device - click OK.
- Quickly, three times click one of the buttons.
- LED will start blinking yellow, wait for the removing process to end.
- Successful removing will be confirmed by the Z-Wave controller’s message and red LED colour.
Operating the device
Calibration
Calibration is a process during which a device learns the position of the limit switches and a motor characteristic.
Calibration is mandatory in order for the device to correctly recognize a roller blind position.
The procedure consists of an automatic, full movement between the limit switches (up, down, and up again).
Button description:
– 1st button, for up movement
– 2nd button, for down movement
Automatic positioning of standard roller blind using the menu
- Set parameter 151 to 1 (default).
- Quickly, three times click, then press and hold one of the buttons to enter the menu.
- Release button when the device glows white.
- Quickly click the button to confirm.
- The device will perform the calibration process, completing full cycle – up, down and up again. During the calibration the LED frame blinks white.
- Test whether the positioning works correctly.
Automatic positioning of standard roller blind using the parameter
- Set parameter 151 to 1 (default).
- Set parameter 150 to 2.
- The device will perform the calibration process, completing full cycle – up, down and up again. During the calibration the LED frame blinks white.
- Test whether the positioning works correctly.
Manual positioning of slats in venetian blinds mode
- Set parameter 151 to 2.
- Calibrate blinds as standard ones (described above).
- By default, time of transition between extreme positions is set to 150 (1.5 seconds) in parameter 152.
- Turn slats between extreme positions by holding
or
button:
- If after full cycle a blind starts moving up or down – decrease value of parameter 152,
- If after full cycle the slats does not reach end positions – increase value of parameter 152,
- Repeat previous step until satisfactory positioning is achieved.
- Test whether the positioning works correctly. Correctly configured slats should not force the blinds to move up or down.
Manual positioning of roller blind with built-in driver
- Set parameter 151 to 5 or 6.
- By default, time of transition between extreme positions is set to 6000 (60 seconds) in parameters 156 and 157.
- Move roller blinds between extreme positions by clicking
or
switch:
- If roller blind stops before reaching top – increase value of parameter 156,
- If roller blind does not stop after reaching top – decrease value of parameter 156,
- If roller blind stops before reaching bottom – increase value of parameter 157,
- If roller blind does not stop after reaching bottom – decrease value of parameter 157,
- Repeat previous step until satisfactory positioning is achieved.
- Test whether the positioning works correctly.
Controls
Button control
Operating roller blinds (configurable using parameter 24)
- Click
– initiate up movement.
- Click
– initiate down movement.
If the blind is moving, clicking any button, will stop the movement.
Operating slats of venetian blinds
- Hold
– initiate slats rotation up.
- Hold
– initiate slats rotation down.
Release to stop the movement.
Other actions
Perform following actions on one of the buttons to:
- 3xClick – start learn mode to add/remove to/from Z-Wave network,
- 1,2,3xClick/hold/release – activate scene in the controller for specific action (requires configuration using parameters 40 and 41)
- 3xClick then press and hold – enter the menu.
Visual indications
The built-in LED light shows current device status.
After powering the device:
- Green – device added to a Z-Wave network (non-secure, S0, S2 non-authenticated),
- Magenta – device added to a Z-Wave network (Security S2 Authenticated),
- Red – device not added to a Z-Wave network.
State of the device:
- White – load turned ON (configurable using parameters 11 and 12).
Update:
- Blinking cyan – update in progress,
- Green – update successful,
- Red – update not successful.
Menu:
- Blinking green – entering the menu (added as non-secure, S0, S2 non-authenticated),
- Blinking magenta – entering the menu (added as Security S2 Authenticated),
- Blinking red – entering the menu (not added to a Z-Wave network),
- White – start calibration,
- Green – reset energy consumption memory,
- Yellow – reset to factory defaults.
Menu
Menu allows to perform Z-Wave network actions. In order to use the menu:
- Quickly, three times click, then press and hold one of the buttons to enter the menu, device blinks to signal adding status (see: Visual indications).
- Release the button when device signals desired position with colour:
- WHITE – start calibration
- GREEN – reset energy consumption memory
- MAGENTA – start range test
- YELLOW – reset to factory defaults
- Quickly click the button to confirm.
Resetting to factory defaults
Reset procedure allows to restore the device back to its factory settings, which means all information about the Z-Wave controller and user configuration will be deleted. Resetting to factory defaults does not reset energy consumption memory.
Resetting the device is not the recommended way of removing the device from the Z-Wave network. Use reset procedure only if the primary controller is missing or inoperable. Certain device removal can be achieved by the procedure of removing described.
- Quickly, three times click, then press and hold one of the buttons to enter the menu.
- Release button when the device glows yellow.
- Quickly click the button to confirm.
- After few seconds the device will be restarted, which is signalled with red LED colour.
Additional features
Power and energy metering
The device allows for the active power and energy consumption monitoring. Data is sent to the main Z-Wave controller, e.g. Home Center.
Measuring is carried out by the most advanced microcontroller technology, assuring maximum accuracy and precision (+/- 1% for loads greater than 10W).
Electric active power – power that energy receiver is changing into a work or a heat. The unit of active power is Watt [W].
Power measurement can contain mains voltage fluctuations within +/- 10%.
Electric energy – energy consumed by a device through a time period. Consumers of electricity in households are billed by suppliers on the basis of active power used in given unit of time. Most commonly measured in kilowatt-hour [kWh]. One kilowatt-hour is equal to one kilowatt of power consumed over period of one hour,
1kWh = 1000Wh.
Resetting consumption memory:
- Quickly, three times click, then press and hold one of the buttons to enter the menu.
- Release button when the device glows green.
- Quickly click the button to confirm.
- Device will blink two times green to confirm.
The device stores periodically (every hour) the consumption data in the device memory. Disconnecting the module from the power supply will not erase stored energy consumption data.
Configuration
Associations
Association (linking devices) – direct control of other devices within the Z-Wave system network.
Associations allow:
- reporting the device status to the Z-Wave controller (using Lifeline group),
- creating simple automations by controlling other devices without participation of the main controller (using groups assigned to actions on the device)
Commands send to 2nd and 3rd association groups reflect button operation according to device configuration, e.g. starting the blinds movement using button will send frame responsible for the same action.
The device provides the association of 3 groups:
1st association group – “Lifeline” reports the device status and allows for assigning single device only (main controller by default).
2nd association group – “Roller Shutter” is assigned to shutter position control – UP/DOWN (uses Switch Multilevel command class).
3rd association group – “Slats” is assigned to slats position control – UP/DOWN (uses Switch Multilevel command class).
The device allows to control 5 regular or multichannel devices per an association group, with the exception of “LifeLine” that is reserved solely for the controller and hence only 1 node can be assigned.
Advanced parameters
The device allows customizing its operation to user’s needs using configurable parameters.
The settings can be adjusted via the Z-Wave controller to which the device is added. The way of adjusting them might differ depending on the controller.
In the FIBARO interface parameters are presented as simple options in the Advanced Settings of the device.
Available parameters:
This parameter defines the LED colour when the motor is running.
Parameter size: 1B
Default value: 1 (white)
Available values:
0 – LED disabled
1 – White
2 – Red
3 – Green
4 – Blue
5 – Yellow
6 – Cyan
7 – Magenta
This parameter defines the LED colour when the device motor is not running.
Parameter size: 1B
Default value: 0 (disabled)
Available values:
0 – LED disabled
1 – White
2 – Red
3 – Green
4 – Blue
5 – Yellow
6 – Cyan
7 – Magenta
This parameter allows to adjust the LED frame brightness.
Parameter size: 1B
Default value: 100 (100%)
Available values:
0 – LED disabled
1-100 (1-100% brightness)
This parameter allows reversing the operation of the buttons.
Parameter size: 1B
Default value: 0
Available values:
0 – default (1st button UP, 2nd button DOWN)
1 – reversed (1st button DOWN, 2nd button UP)
This parameter allows reversing the operation of Q1 and Q2 without changing the wiring (e.g. in case of invalid motor connection).
Parameter size: 1B
Default value: 0
Available values:
0 – default (Q1 – UP, Q2 – DOWN)
1 – reversed (Q1 – DOWN, Q2 – UP)
This parameter determines to which alarm frames and how the device should react. The parameters consist of 4 bytes, three most significant bytes are set according to the official Z-Wave protocol specification.
Parameter size: 4B
Default value: [0x00, 0x00, 0x00, 0x00] (disabled)
Available values:
1B [MSB] – Notification Type
2B – Notification Status
3B – Event/State Parameters
4B [LSB] – action:
0x00 – no action, 0xX1 – open, 0xX2 – close, 0x0X – no action on LED frame, 0x1X – LED frame blinks red, 0x2X – LED frame blinks green, 0x4X – LED frame blinks blue, 0x8X – disable LED frame, 0xFX – LED frame LAPD signal (red-white-blue)
This parameter determines to which alarm frames and how the device should react. The parameters consist of 4 bytes, three most significant bytes are set according to the official Z-Wave protocol specification.
Parameter size: 4B
Default value
[0x05, 0xFF, 0x00, 0x00](Water Alarm, any notification, no action)
Available values:
1B [MSB] – Notification Type
2B – Notification Status
3B – Event/State Parameters
4B [LSB] – action:
0x00 – no action, 0xX1 – open, 0xX2 – close, 0x0X – no action on LED frame, 0x1X – LED frame blinks red, 0x2X – LED frame blinks green, 0x4X – LED frame blinks blue, 0x8X – disable LED frame, 0xFX – LED frame LAPD signal (red-white-blue)
This parameter determines to which alarm frames and how the device should react. The parameters consist of 4 bytes, three most significant bytes are set according to the official Z-Wave protocol specification.
Parameter size: 4B
Default value
[0x01, 0xFF, 0x00, 0x00](Smoke Alarm, any notification, no action)
Available values:
1B [MSB] – Notification Type
2B – Notification Status
3B – Event/State Parameters
4B [LSB] – action:
0x00 – no action, 0xX1 – open, 0xX2 – close, 0x0X – no action on LED frame, 0x1X – LED frame blinks red, 0x2X – LED frame blinks green, 0x4X – LED frame blinks blue, 0x8X – disable LED frame, 0xFX – LED frame LAPD signal (red-white-blue)
This parameter determines to which alarm frames and how the device should react. The parameters consist of 4 bytes, three most significant bytes are set according to the official Z-Wave protocol specification.
Parameter size: 4B
Default value
[0x02, 0xFF, 0x00, 0x00](CO Alarm, any notification, no action)
Available values:
1B [MSB] – Notification Type
2B – Notification Status
3B – Event/State Parameters
4B [LSB] – action:
0x00 – no action, 0xX1 – open, 0xX2 – close, 0x0X – no action on LED frame, 0x1X – LED frame blinks red, 0x2X – LED frame blinks green, 0x4X – LED frame blinks blue, 0x8X – disable LED frame, 0xFX – LED frame LAPD signal (red-white-blue)
This parameter determines to which alarm frames and how the device should react. The parameters consist of 4 bytes, three most significant bytes are set according to the official Z-Wave protocol specification.
Parameter size: 4B
Default value
[0x04, 0xFF, 0x00, 0x00](Heat Alarm, any notification, no action)
Available values:
1B [MSB] – Notification Type
2B – Notification Status
3B – Event/State Parameters
4B [LSB] – action:
0x00 – no action, 0xX1 – open, 0xX2 – close, 0x0X – no action on LED frame, 0x1X – LED frame blinks red, 0x2X – LED frame blinks green, 0x4X – LED frame blinks blue, 0x8X – disable LED frame, 0xFX – LED frame LAPD signal (red-white-blue)
This parameter defines duration of alarm sequence. When time set in this parameter elapses, alarm is cancelled, LED frame and relay restore normal operation, but do not recover state from before the alarm.
Parameter size: 2B
Default value: 600 (10min)
Available values:
0 – infinite
1-32400 (1s-9h, 1s step) – duration
This parameter determines which actions result in sending scene IDs assigned to them. Values can be combined (e.g. 1+2=3 means that scenes for single and double click are sent).
Enabling scenes for triple click disables entering the device in learn mode by triple clicking.
Parameter size: 1B
Default value: 0 (no scenes)
Available values:
1 – Key pressed 1 time
2 – Key pressed 2 times
4 – Key pressed 3 times
8 – Key hold down and key released
This parameter determines which actions result in sending scene IDs assigned to them. Values can be combined (e.g. 1+2=3 means that scenes for single and double click are sent).
Enabling scenes for triple click disables entering the device in learn mode by triple clicking.
Parameter size: 1B
Default value: 0 (no scenes)
Available values:
1 – Key pressed 1 time
2 – Key pressed 2 times
4 – Key pressed 3 times
8 – Key hold down and key released
This parameter determines whether the power measurements should include power consumed by the device itself.
Parameter size: 1B
Default value: 0 (not included)
Available values:
0 – self-consumption not included
1 – self-consumption included
This parameter defines minimal change (from the last reported) in measured power that results in sending new report. For loads under 50W the parameter is irrelevant, report are sent every 5W change.
Parameter size: 2B
Default value: 15 (15%)
Available values:
0 – reporting on change disabled
1-500 (1-500%, 1% step) – minimal change
This parameter defines reporting interval for measured power. Periodic reports are independent from changes in value (parameter 61).
Parameter size: 2B
Default value: 3600 (1h)
Available values:
0 – periodic reports disabled
30-32400 (30s-9h, 1s step) – time interval
This parameter defines minimal change (from the last reported) in measured energy that results in sending new report.
Parameter size: 2B
Default value: 10 (0.1kWh)
Available values:
0 – reporting on change disabled
1-500 (0.01-5kWh, 0.01kWh step) – minimal change
This parameter defines reporting interval for measured energy. Periodic reports are independent from changes in value (parameter 65).
Parameter size: 2B
Default value: 3600 (1h)
Available values:
0 – periodic reports disabled
30-32400 (30s-9h, 1s step) – time interval
By setting this parameter to 2 the device enters the calibration mode. The parameter relevant only if the device is set to work in positioning mode (parameter 151 set to 1 or 2).
Parameter size: 1B
Default value: 0
Available values:
0 – device is not calibrated
1 – device is calibrated
2 – force device calibration
This parameter allows adjusting operation according to the connected device.
Parameter size: 1B
Default value: 1
Available values:
1 – roller blind (with positioning)
2 – Venetian blind (with positioning)
5 – roller blind with built-in driver
6 – roller blind with built-in driver (impulse)
Description
For Venetian blinds (parameter 151 set to 2) the parameter determines time of full turn cycle of the slats.
The parameter is irrelevant for other modes.
Parameter size: 4B
Default value: 150 (1.5 seconds)
Available values:
0-65535 (0 – 655.35s, every 0.01s) – time of turn
For Venetian blinds (parameter 151 set to 2) the parameter determines slats positioning in various situations.
The parameter is irrelevant for other modes.
Parameter size: 1B
Default value: 1
Available values:
0 – slats return to previously set position only in case of the main controller operation
1 – slats return to previously set position in case of the main controller operation, momentary switch operation, or when the limit switch is reached
2 – slats return to previously set position in case of the main controller operation, momentary switch operation, when the limit switch is reached or after receiving the Switch Multilevel Stop control frame
The parameter determines the time after which the motor will be stopped after end switch contacts are closed.
Parameter size: 2B
Default value: 10 (1 second)
Available values:
1-255 (0.1s – 25.5 seconds)
Power threshold interpreted as reaching a limit switch.
Parameter size: 2B
Default value: 10 (10W)
Available values:
1-255 (1-255W) – report interval
0 – no detection
This parameter determines the time needed for roller blinds to reach the top.For modes with positioning value is set automatically during calibration, otherwise, it must be set manually.
Parameter size: 4B
Default value: 6000 (60 seconds)
Available values:
1-65535 (0.01 – 655.35 seconds)
This parameter determines the time needed for roller blinds to reach the bottom.For modes with positioning value is set automatically during calibration, otherwise, it must be set manually.
Parameter size: 4B
Default value: 6000 (60 seconds)
Available values:
1-65535 (0.01 – 655.35 seconds)