Description and features

Description

FIBARO Walli Dimmer is a smart wall dimmer designed to control light source via Z-Wave network.

It measures active power and energy consumed by the controlled load.

You can install it with provided cover plate and switch button or other compatible.

Back To Top

Main features

  • Can be used for dimming:
    • 110/230V operated conventional incandescent and halogen,
    • 12V operated ELV halogen lamps and dimmable LED bulbs (with electronic transformers),
    • 12V operated MLV halogen lamps (with ferromagnetic transformers),
    • dimmable LED bulbs,
    • dimmable compact fluorescent CFL tube lamps,
    • supported dimmable light sources (power factor > 0.5) with minimal power of 5VA using FIBARO Bypass 2.
  • Can be used for switching:
    • compact fluorescent CFL tube lamps with electronic ballast,
    • fluorescent tube lamps with electronic ballast,
    • LED bulbs (power factor > 0.7),
    • supported light sources (power factor > 0.5) with minimal power of 5VA using FIBARO Bypass 2.
  • Uses different operating modes:
    • „Trailing edge” for resistive loads (R)
    • „Trailing edge” for resistive-capacitive loads (RC)
    • „Leading edge” for resistive-inductive loads (RL)
  • Can be used with FIBARO Walli covers or other compatible (see “Parts compatibility”):
    • GIRA – System 55 (Standard 55, E2, Event, Event Clear),
    • Legrand – Céliane,
    • Schneider – Odace.
  • Active power and energy consumption metering.
  • Can be installed in two and three-wired configuration.
  • Calibrates automatically to the connected light source.
  • Supports Z-Wave network Security Modes: S0 with AES-128 encryption and S2 Authenticated with PRNG-based encryption.
  • Works as a Z-Wave signal repeater (all non-battery operated devices within the network will act as repeaters to increase reliability of the network).
  • May be used with all devices certified with the Z-Wave Plus certificate and should be compatible with such devices produced by other manufacturers.

The device is a Security Enabled Z-Wave Plus product and a Security Enabled Z-Wave Controller must be used in order to fully utilize the product.

Back To Top

Specifications

Power supply 110-230V~ 50/60 Hz
Compatible load types Resistive loads
Conventional incandescent and halogen light sources
Resistive-capacitive loads
Fluorescent tube lamp (compact / with electronic ballast), electronic transformer, LED
Resistive-inductive loads
Ferromagnetic transformers
Rated load current 0.22A-1.52A – resistive loads (incandescent and halogen)
0.22A-1.3A – resistive-capacitive loads (fluorescent tube lamp, electronic transformer, LED)
0.22A-1.3A – resistive-inductive loads (ferromagnetic transformers)
0.022A-0.22A – with Bypass 2: fluorescent tube lamp or LED
Active element semiconductor electronic switch ε
Recommended external overcurrent protection 10A type B circuit breaker (EU)
13A type B circuit breaker (Sweden)
For installation in boxes Ø = 60mm, depth ≥ 40mm
Recommended wires cross-section area between 1.5-4.0mm2,
stripped 12-12.5mm of insulation
Operating temperature 0–35°C
Ambient humidity 10–95% RH without condensation
Radio protocol Z-Wave (500 series chip)
Radio frequency band 868.0–868.6MHz; 869.7–870.0MHz
Max. transmitting power +6dBm
Range up to 50m outdoors
up to 40m indoors
(depending on terrain and building structure)
Dimensions
(Height x Width x Depth)
86 x 86 x 51 mm
Compliance with EU directives RoHS 2011/65/EU
RED 2014/53/EU

Radio frequency of individual device must be same as your Z-Wave controller. Check information on the box or consult your dealer if you are not sure.

Back To Top

Important safety information

Read this manual before attempting to install the device!

Failure to observe recommendations included in this manual may be dangerous or cause a violation of the law. The manufacturer, Fibar Group S.A. will not be held responsible for any loss or damage resulting from not following the instructions of operating manual.

  • DANGER OF ELECTROCUTION!
    • The device is designed to operate in electrical home installation. Faulty connection or use may result in fire or electric shock.
    • All works on the device may be performed only by a qualified and licensed electrician. Observe national regulations.
    • Even when the device is turned off, voltage may be present at its terminals. Any maintenance introducing changes into the configuration of connections or the load must be always performed with disabled fuse.
    • To avoid risk of electrical shock, do not operate the device with wet or moist hands.
  • Do not modify!
    Do not modify this device in any way not included in this manual.
  • Other devices
    The manufacturer, Fibar Group S.A. will not be held responsible for any damage or loss of warranty privileges for other connected devices if the connection is not compliant with their manuals.
  • This product is intended for indoor use only in dry locations.
    Do not use in damp or wet locations, near a bathtub, sink, shower, swimming pool, or anywhere else where water or moisture are present.
  • Not a toy!
    This product is not a toy. Keep away from children and animals!

Back To Top

FIBARO Bypass 2 (FGB-002)

FIBARO Bypass 2 (FGB-002) is a device designed to work with FIBARO Dimmer 2 (FGD-212) and Walli Dimmer (FGWDEU-111). It should be used in case of connecting LED bulbs or energy saving compact fluorescent lamps. FIBARO Bypass 2 prevents flickering of the LED lights and glowing of the turned off compact fluorescent lamps.

In the case of 2-wire connection, FIBARO Bypass 2 allows to reduce minimum power of load required by the Dimmer for correct operation. FGB-002 provides powering of the Dimmer in case of controlling the low loads of minimum power down to 5VA (for cosφ>0.5).

In the case of 2-wire connection do not connect load below minimal power without FGB-002.

Bypass 2 works only in trailing edge mode. Do not connect the Bypass 2 to the Dimmer operating in leading edge mode.

Bypass 2 is sensitive to the frequent changes of the state of Dimmer (alternate switching on and off). Significant changes in brightness should not be performed more than once per second.

Back To Top

Installation

Before installation

Connecting the device in a manner inconsistent with this manual may cause risk to health, life or material damage.

  • Do not power the device before fully assembling it in the mounting box,
  • Connect only in accordance with one of the diagrams,
  • Install only in flush mounting boxes compliant with a relevant national safety standards and with depth no less than 40mm,
  • Do not connect devices which are not compliant with the specification or relevant safety standards,
  • Do not connect heating devices,
  • Do not connect SELV or PELV circuits,
  • Do not connect loads below minimal power in 2-wire connection without Bypass 2.
  • Do not connect different types of light sources simultaneously
  • Do not connect the power supply without a load
  • Do not connect more than one transformer
  • When using magnetic transformer load it with 50% of its nominal power at minimum
  • Minimize number of electronic transformers in a circuit, noises caused by them in electrical grids may affect device operation.
  • Make sure you have all required parts when installing with covers other than FIBARO (see “Parts compatibility”).

Device parts:

1 – switch button, 2 – cover plate, 3 – unit (device), 4 – mounting frame

Notes for diagrams:

N – terminal for neutral wire

S – support terminal of 2-wire connection

L – terminal for live wire

Q – output terminal for controlled load

G – groove used to measure wire length

 

Back To Top

Preparing for installation

Prepare wires by removing 12-12.5mm of insulation from their ends. You can use groove on the side of the unit to measure the length.

When installing with FIBARO or GIRA covers:

  1. Pull out the switch button.
  2. Take off the cover plate.

When installing with Legrand or Schneider covers:

  1. Pull out the original switch button.
  2. Take off the original cover plate.
  3. Dismount the original mounting frame.
  4. Snap the new mounting frame*.

* Additional mounting frames are sold separately.

Back To Top

Electrical connection

  1. Switch off the mains voltage (disable the fuse).
  2. Connect with one of the diagrams below:

    Diagram 1: Example connection for 3-wire installation

    Diagram 2: Example connection for 3-wire installation with Bypass 2

    Diagram 3: Example connection for 2-wire installation

    Diagram 4: Example connection for 2-wire installation with Bypass 2

  3. Verify correctness of connection.
  4. Tighten the terminal screws using PH1 screwdriver.

Back To Top

Assembling the device

When installing the device in the mounting box orient the device with terminal screws going up or to the left (for horizontal button position) to ensure button order.

When installing with covers other than FIBARO, we recommend disabling the LED by changing parameter 13 to 0.

When installing with FIBARO covers:

  1. Insert the device with mounting frame into the mounting box and secure with mounting claws and screws.
  2. Snap the cover plate to the device.
  3. Snap the switch button to the device.

When installing with GIRA covers:

  1. Insert the device with mounting frame into the mounting box and secure with mounting claws and screws.
  2. Snap the new cover plate to the device.
  3. Snap the switch button adapter* to the device.
  4. Snap the new switch button to the device.

When installing with Legrand covers:

  1. Insert the device with mounting frame* into the mounting box and secure with mounting claws and screws.
  2. Snap the switch button adapter* to the device.
  3. Snap the new inner cover plate to the device.
  4. Snap the new outer cover plate to the device.
  5. Snap the new switch button to the device.

When installing with Schneider covers:

  1. Insert the device with mounting frame* into the mounting box and secure with mounting claws and screws.
  2. Snap the new cover plate to the device.
  3. Snap the new switch button to the device.

* Switch button adapter and additional mounting frames are sold separately.

Back To Top

Activating the device

  1. If the device fully assembled, switch on the mains voltage.
  2. LED ring light means the device is powered.
  3. Wait for the calibration process to end. Light may blink, the device will be switched off once the process is completed.
  4. The device can be added to the Z-Wave network.

Back To Top

Parts compatibility

Available FIBARO parts

Included in FGWDEU-111

Name

Symbol

Walli Dimmer Unit

FG-WDEU111-AS-8001

x

Switch Button with Lightguide

FG-WDSEU221-AS-8100

x

Switch Button Adapter

FG-WDSEU221-PP-0007

Mounting Frame FIBARO/GIRA

FG-Wx-AS-4001

x

Mounting Frame Legrand

FG-Wx-AS-4002

Mounting Frame Schneider

FG-Wx-AS-4003

Single Cover Plate

FG-Wx-PP-0001

x

Double Cover Plate

FG-Wx-PP-0003

Triple Cover Plate

FG-Wx-PP-0004

 

Parts required for GIRA System 55 (only with non-metalised outer surface: Standard 55, E2, Event, Event Clear) covers

Required FIBARO parts

Name

Symbol

Walli Dimmer Unit

FG-WDEU111-AS-8001

Switch Button Adapter

FG-WDSEU221-PP-0007

Mounting Frame FIBARO/GIRA

FG-Wx-AS-4001

 

Parts required for Legrand Céliane covers

Required FIBARO parts

Name

Symbol

Walli Dimmer Unit

FG-WDEU111-AS-8001

Switch Button Adapter

FG-WDSEU221-PP-0007

Mounting Frame Legrand

FG-Wx-AS-4002

 

Parts required for Schneider Odace covers

Required FIBARO parts

Name

Symbol

Walli Dimmer Unit

FG-WDEU111-AS-8001

Mounting Frame Schneider

FG-Wx-AS-4003

 

Back To Top

Z-Wave network

Adding to Z-Wave network

Adding (Inclusion) – Z-Wave device learning mode, allowing to add the device to existing Z-Wave network.

Adding manually

To add the device to the Z-Wave network manually:

  1. Set the main controller in (Security/non-Security Mode) add mode (see the controller’s manual).
  2. Quickly, three times click one of the buttons.
  3. If you are adding in Security S2 Authenticated, input the underlined part of the DSK (label on the bottom of the box).
  4. LED will start blinking yellow, wait for the adding process to end.
  5. Adding result will be confirmed by the Z-Wave controller’s message and the LED frame:
    • Green – successful (non-secure, S0, S2 non-authenticated),
    • Magenta – successful (Security S2 Authenticated),
    • Red – not successful.

Adding using SmartStart

SmartStart enabled products can be added into a Z-Wave network by scanning the Z-Wave QR Code present on the product with a controller providing SmartStart inclusion. SmartStart product will be added automatically within 10 minutes of being switched on in the network range.

To add the device to the Z-Wave network using SmartStart:

  1. To use SmartStart your controller needs to support Security S2 (see the controller’s manual).
  2. Enter the full DSK string code to your controller. If your controller is capable of QR scanning, scan the QR code placed on the label on the bottom of the box.
  3. Power the device.
  4. Wait for the calibration process to end. Light may blink, the device will be switched off once the process is completed.
  5. Wait for the adding process to start (up to few minutes), which is signalled with yellow LED blinking.
  6. Adding result will be confirmed by the Z-Wave controller’s message and the LED frame:
    • Green – successful (non-secure, S0, S2 non-authenticated),
    • Magenta – successful (Security S2 Authenticated),
    • Red – not successful.

In case of problems with adding the device, please reset the device and repeat the adding procedure.

Back To Top

Removing from Z-Wave network

Removing (Exclusion) – Z-Wave device learning mode, allowing to remove the device from existing Z-Wave network. Removing also results in resetting the device to factory defaults.

To remove the device from the Z-Wave network:

  1. Set the main controller into remove mode (see the controller’s manual).
  2. Quickly, three times click one of the buttons.
  3. LED will start blinking yellow, wait for the removing process to end.
  4. Successful removing will be confirmed by the Z-Wave controller’s message and red LED colour.
  5. The device will start calibrating the load.

Removing device won't be possible if the central scene notifications have been activated by parameter 40 and 41.

Back To Top

Operating the device

Calibration

The device is equipped with an algorithm of smart light source detection. It automatically selects suitable control mode (leading edge for inductive loads, trailing edge for capacitive or resistive loads) and adjusts maximum and minimum light levels.

Installer is obliged to verify the proper operation of the device. There is a small probability that calibration settings will require a manual correction.

In a 2-wire connection for non-resistive loads minimum level (parameter 150) must be adjusted manually.

In a 2-wire connection if calibration results in Voltage Drop error, maximum level (parameter 151) must be adjusted manually.

Some types of LED and CF lamps are designed to operate in leading edge mode (with conventional dimmers).

The device starts calibration automatically depending on parameter 175 or can be started manually by:

  • Setting parameter 159 to 1 or 2 (without or with Bypass 2),
  • Selecting blue or red (without or with Bypass 2) menu position.

The result of calibration will be confirmed by the LED frame:

  • GREEN – Light source recognized as dimmable, dimming levels set,
  • YELLOW – Light source recognized as non-dimmable, only switching possible,
  • RED – Calibration failed: lack of connected load or connected light source exceeds maximum power,
  • BLINKING RED – Calibration failed: installation failure or damaged load.

Back To Top

Controls

  1. First/smart blinds button,
  2. Second/smart blinds button,
  3. LED ring.

Back To Top

Button control

Controlling connected load

Perform following actions on one of the buttons to change state of the connected load.

  • Click smart blinds if turned off – turn on with previous level,
  • Click smart blinds if turned on – set to 100%,
  • 2xClick smart blinds – set to 100%,
  • Click smart blinds – turn off,
  • Hold smart blinds – start brightening until released,
  • Hold smart blinds – start dimming until released.

Other actions

Perform following actions on one of the buttons to:

  • 3xClick – start learn mode to add/remove to/from Z-Wave network,
  • 1,2,3xClick/hold/release – activate scene in the controller for specific action (requires prior configuration),
  • 3xClick then press and hold – enter the menu.

Back To Top

Visual indications

The built-in LED light shows current device status.

After powering the device:

  • Green – device added to a Z-Wave network (non-secure, S0, S2 non-authenticated),
  • Magenta – device added to a Z-Wave network (Security S2 Authenticated),
  • Red – device not added to a Z-Wave network.

State of the device:

  • White – load turned ON (configurable).

Update:

  • Blinking cyan – update in progress,
  • Green – update successful,
  • Red – update not successful.

Menu:

  • Blinking green – entering the menu (added as non-secure, S0, S2 non-authenticated),
  • Blinking magenta – entering the menu (added as Security S2 Authenticated),
  • Blinking red – entering the menu (not added to a Z-Wave network),
  • Blue – start load calibration
  • Red – start load calibration with FIBARO Bypass 2
  • Green – reset energy consumption memory,
  • Yellow – reset to factory defaults.

Back To Top

Menu

Menu allows to perform Z-Wave network actions. In order to use the menu:

  1. Quickly, three times click, then press and hold one of the buttons to enter the menu, device blinks to signal adding status (see: Visual indications).
  2. Release the button when device signals desired position with colour:
    • BLUE – start load calibration
    • RED – start load calibration with FIBARO Bypass 2
    • GREEN – reset energy consumption memory
    • MAGENTA – start Z-Wave range test
    • YELLOW – reset to factory defaults
  3. Quickly click the button to confirm.

Back To Top

Resetting to factory defaults

Reset procedure allows to restore the device back to its factory settings, which means all information about the Z-Wave controller and user configuration will be deleted. Resetting to factory defaults does not reset energy consumption memory.

Resetting the device is not the recommended way of removing the device from the Z-Wave network. Use reset procedure only if the primary controller is missing or inoperable. Certain device removal can be achieved by the procedure of removing described.

  1. Quickly, three times click, then press and hold one of the buttons to enter the menu.
  2. Release the button when the device glows yellow.
  3. Quickly click the button to confirm.
  4. After a few seconds the device will be restarted, which is signalled with red LED colour.

Back To Top

Additional features

Power and energy metering

The device allows for the active power and energy consumption monitoring. Data is sent to the main Z-Wave controller, e.g. Home Center.

Measuring is carried out by the most advanced microcontroller technology, assuring maximum accuracy and precision (+/- 1% for loads greater than 10W).

Electric active power – power that energy receiver is changing into a work or a heat. The unit of active power is Watt [W].

Power measurement can contain mains voltage fluctuations within +/- 10%.

Electric energy – energy consumed by a device through a time period. Consumers of electricity in households are billed by suppliers on the basis of active power used in given unit of time. Most commonly measured in kilowatt-hour [kWh]. One kilowatt-hour is equal to one kilowatt of power consumed over period of one hour,
1kWh = 1000Wh.

Resetting consumption memory:

  1. Quickly, three times click, then press and hold one of the buttons to enter the menu.
  2. Release button when the device glows green.
  3. Quickly click the button to confirm.
  4. Device will blink two times green to confirm.

The device stores periodically the consumption data in the device memory. Disconnecting the module from the power supply will not erase stored energy consumption data.

3-wire connection

Brightness>70%

Brightness<70%

resistive load

±(0.5%+0.2W)

±(2%+0.2W)

resistive-inductive load

±(0.5%+0.2W)

±(2%+0.2W)

resisitve-capacitive load

±(0.5%+0.2W)

±(2%+0.2W)

 

 

2-wire connection

Brightness>70%

Brightness<70%

resistive load

±(2%+0.2W)

±(4%+0.2W)

resistive-inductive load

Approximated*

Approximated*

resisitve-capacitive load

Approximated*

Approximated*

* Measurements are only illustrative, returned values may differ from the actual measurement. In the case of reporting incorrect values change the values of parameters 178 and 179.

Back To Top

Configuration

Associations

Association (linking devices) – direct control of other devices within the Z-Wave system network.

Associations allow:

  • reporting the device status to the Z-Wave controller (using Lifeline group),
  • creating simple automations by controlling other devices without participation of the main controller (using groups assigned to actions on the device).

Commands send to 2nd and 3rd association groups reflect button operation according to device configuration, e.g. turning the load on using button will send frame responsible for the same action.

The device provides the association of 3 groups:

1st association group – “Lifeline” reports the device status and allows for assigning single device only (main controller by default).

2nd association group – “On/Off” is used to turn the associated devices on/off reflecting button operation (uses Basic command class).

3rd association group – “Dimmer” is used to change level of associated devices reflecting button operation (uses Switch Multilevel command class).

The device allows to control 5 regular or multichannel devices per an association group, with the exception of “LifeLine” that is reserved solely for the controller and hence only 1 node can be assigned.

Commands sent to association groups

1 click

2 click

Hold

Release

Button 1

Basic Set: 2nd group,
Multilevel
Set: 3rd group

Basic Set: 2nd group,
Multilevel
Set: 3rd group

Multilevel Start Change: 3rd group

Multilevel Stop Level Change: 3rd group

Button 2

Basic Set: 2nd group,
Multilevel
Set: 3rd group

Multilevel Start Change: 3rd group

Multilevel Stop Level Change: 3rd group

Back To Top

Advanced parameters

The device allows to customize its operation to user’s needs using configurable parameters.

The settings can be adjusted via Z-Wave controller to which the device is added. The way of adjusting them might differ depending on the controller.

In the FIBARO interface parameters are presented as simple options in Advanced Settings of the device.

Available parameters:

This parameter determines how the device will react in the event of power supply failure (e.g. power outage).

Parameter size: 1B

Default value: 1 (restores the state)

Available values:

0 – remains switched off after restoring power

1 – restores remembered state after restoring power

This function allows to turn off the controlled device in case of exceeding the defined power. Controlled device can be turned back on via the button or sending a control frame.

Parameter size: 4B

Default value: 3500 (350W)

Available values:

0 – function disabled

10-5000 (1.0-500.0W, step 0.1W) – power threshold

This parameter determines maximum active power. Exceeding it results in the LED frame flashing violet. Function is active only when parameter 11 is set to 8 or 9.

Parameter size: 4B

Default value: 3500 (350W)

Available values:

100-5000 (10.0-500.0W, step 0.1W) – power threshold

This parameter defines the LED colour when the device is ON.

When set to 8 or 9, LED frame colour will change depending on the measured power and parameter 10. Other colours are set permanently and do not depend on power consumption.

Parameter size: 1B

Default value: 1 (white)

Available values:

0 – LED disabled

1 – White

2 – Red

3 – Green

4 – Blue

5 – Yellow

6 – Cyan

7 – Magenta

8 – colour changes smoothly depending on measured power

9 – colour changes in steps depending on measured power

This parameter defines the LED colour when the device is OFF.

Parameter size: 1B

Default value: 0 (disabled)

Available values:

0 – LED disabled

1 – White

2 – Red

3 – Green

4 – Blue

5 – Yellow

6 – Cyan

7 – Magenta

This parameter allows to adjust the LED frame brightness.

Parameter size: 1B

Default value: 100 (100%)

Available values:

0 – LED disabled

1-100 (1-100% brightness)

101 – brightness directly proportional to set level

102 – brightness inversely proportional to set level

This parameter allows reversing the operation of the buttons.

Parameter size: 1B

Default value: 0

Available values:

0 – default (1st button brightens, 2nd button dims)

1 – reversed (1st button dims, 2nd button brightens)

This parameter determines to which alarm frames and how the device should react. The parameters consist of 4 bytes, three most significant bytes are set according to the official Z-Wave protocol specification.

Parameter size: 4B

Default value: [0x00, 0x00, 0x00, 0x00] (disabled)

Available values:

1B [MSB] – Notification Type

2B – Notification Status

3B – Event/State Parameters

4B [LSB] – action:

0x00 – no action,
0xX1 – turn ON,
0xX2 – turn OFF,
0xX3 – turn ON/OFF continuously,
0x0X – no action on LED frame,
0x1X – LED frame blinks red,
0x2X – LED frame blinks green,
0x4X – LED frame blinks blue,
0x8X – disable LED frame,
0xFX – LED frame LAPD signal (red-white-blue)

This parameter determines to which alarm frames and how the device should react. The parameters consist of 4 bytes, three most significant bytes are set according to the official Z-Wave protocol specification.

Parameter size: 4B

Default value

[0x05, 0xFF, 0x00, 0x00]

(Water Alarm, any notification, no action)

Available values:

1B [MSB] – Notification Type

2B – Notification Status

3B – Event/State Parameters

4B [LSB] – action:

0x00 – no action,
0xX1 – turn ON,
0xX2 – turn OFF,
0xX3 – turn ON/OFF continuously,
0x0X – no action on LED frame,
0x1X – LED frame blinks red,
0x2X – LED frame blinks green,
0x4X – LED frame blinks blue,
0x8X – disable LED frame,
0xFX – LED frame LAPD signal (red-white-blue)

This parameter determines to which alarm frames and how the device should react. The parameters consist of 4 bytes, three most significant bytes are set according to the official Z-Wave protocol specification.

Parameter size: 4B

Default value

[0x01, 0xFF, 0x00, 0x00]

(Smoke Alarm, any notification, no action)

Available values:

1B [MSB] – Notification Type

2B – Notification Status

3B – Event/State Parameters

4B [LSB] – action:

0x00 – no action,
0xX1 – turn ON,
0xX2 – turn OFF,
0xX3 – turn ON/OFF continuously,
0x0X – no action on LED frame,
0x1X – LED frame blinks red,
0x2X – LED frame blinks green,
0x4X – LED frame blinks blue,
0x8X – disable LED frame,
0xFX – LED frame LAPD signal (red-white-blue)

This parameter determines to which alarm frames and how the device should react. The parameters consist of 4 bytes, three most significant bytes are set according to the official Z-Wave protocol specification.

Parameter size: 4B

Default value

[0x02, 0xFF, 0x00, 0x00]

(CO Alarm, any notification, no action)

Available values:

1B [MSB] – Notification Type

2B – Notification Status

3B – Event/State Parameters

4B [LSB] – action:

0x00 – no action,
0xX1 – turn ON,
0xX2 – turn OFF,
0xX3 – turn ON/OFF continuously,
0x0X – no action on LED frame,
0x1X – LED frame blinks red,
0x2X – LED frame blinks green,
0x4X – LED frame blinks blue,
0x8X – disable LED frame,
0xFX – LED frame LAPD signal (red-white-blue)

This parameter determines to which alarm frames and how the device should react. The parameters consist of 4 bytes, three most significant bytes are set according to the official Z-Wave protocol specification.

Parameter size: 4B

Default value

[0x04, 0xFF, 0x00, 0x00]

(Heat Alarm, any notification, no action)

Available values:

1B [MSB] – Notification Type

2B – Notification Status

3B – Event/State Parameters

4B [LSB] – action:

0x00 – no action,
0xX1 – turn ON,
0xX2 – turn OFF,
0xX3 – turn ON/OFF continuously,
0x0X – no action on LED frame,
0x1X – LED frame blinks red,
0x2X – LED frame blinks green,
0x4X – LED frame blinks blue,
0x8X – disable LED frame,
0xFX – LED frame LAPD signal (red-white-blue)

This parameter defines duration of alarm sequence. When time set in this parameter elapses, alarm is cancelled, LED frame and relay restore normal operation, but do not recover state from before the alarm.

Parameter size: 2B

Default value: 600 (10min)

Available values:

0 – infinite

1-32400 (1s-9h, 1s step) – duration

This parameter determines which actions result in sending scene IDs assigned to them. Values can be combined (e.g. 1+2=3 means that scenes for single and double click are sent).

Enabling scenes for triple click disables entering the device in learn mode by triple clicking.

Parameter size: 1B

Default value: 0 (no scenes)

Available values:

1 – Key pressed 1 time

2 – Key pressed 2 times

4 – Key pressed 3 times

8 – Key hold down and key released

This parameter determines which actions result in sending scene IDs assigned to them. Values can be combined (e.g. 1+2=3 means that scenes for single and double click are sent).

Enabling scenes for triple click disables entering the device in learn mode by triple clicking.

Parameter size: 1B

Default value: 0 (no scenes)

Available values:

1 – Key pressed 1 time

2 – Key pressed 2 times

4 – Key pressed 3 times

8 – Key hold down and key released

This parameter determines whether the power measurements should include power consumed by the device itself.

Parameter size: 1B

Default value: 0 (not included)

Available values:

0 – Self-consumption not included

1 – Self-consumption included

This parameter defines minimal change (from the last reported) in measured power that results in sending new report. For loads under 50W the parameter is irrelevant, report are sent every 5W change.

Parameter size: 2B

Default value: 15 (15%)

Available values:

0 – reporting on change disabled

1-500 (1-500%, 1% step) – minimal change

This parameter defines reporting interval for measured power. Periodic reports are independent from changes in value (parameter 61).

Parameter size: 2B

Default value: 3600 (1h)

Available values:

0 – periodic reports disabled

30-32400 (30s-9h, 1s step) – time interval

This parameter defines minimal change (from the last reported) in measured energy that results in sending new report.

Parameter size: 2B

Default value: 10 (0.1kWh)

Available values:

0 – reporting on change disabled

1-500 (0.01-5kWh, 0.01kWh step) – minimal change

This parameter defines reporting interval for measured energy. Periodic reports are independent from changes in value (parameter 65).

Parameter size: 2B

Default value: 3600 (1h)

Available values:

0 – periodic reports disabled

30-32400 (30s-9h, 1s step) – time interval

This parameter is set automatically during the calibration process, but can be changed manually after the calibration.

Parameter size: 1B

Default value: 1

Available values:

1-98 (1-98%, 1% step) – level of brightness

This parameter is set automatically during the calibration process, but can be changed manually after the calibration.

Parameter size: 1B

Default value: 99

Available values:

2-99 (2-99%, 1% step) – level of brightness

152.

Incandescence level of dimmable compact fluorescent lamps

The virtual value set as a percentage level between parameters MIN (1%) and MAX. (99%). The device will set to this value after the first switch on. It is required for warming up and switching dimmable compact fluorescent lamps and certain types of light sources.

Parameter size: 1B

Default value: 1

Available values:

1-99 (1-98%, 1% step) – level of brightness

153.

Incandescence time of dimmable compact fluorescent lamps

This parameter determines the time required for switching compact fluorescent lamps and certain types of light sources. Setting this parameter to 0 will disable the incandescence functionality.

Parameter size: 2B

Default value: 0

Available values:

0-255 (0-25.5s, 0.1s step) – incandescence time

This parameter defines the percentage value of dimming step during the automatic control.

Parameter size: 1B

Default value: 1

Available values:

1-99 (1-99%, 1% step) – dimming step

This parameter defines the time of performing a single dimming step set in parameter 154 during the automatic control.

Parameter size: 2B

Default value: 1 (10ms)

Available values:

0-255 (0-2.55s, 10ms step)

This parameter defines the percentage value of the dimming step during the manual control.

Parameter size: 1B

Default value: 1

Available values:

1-99 (1-99%, 1% step) – dimming step

This parameter defines the time of performing a single dimming step set in parameter 156 during the manual control.

Parameter size: 2B

Default value: 5 (50ms)

Available values:

0-255 (0-2.55s, 10ms step)

This parameter allows to automatically switch off the device after a specified time from switching the light source on. It may be useful when the device is installed in the stairway.

Parameter size: 2B

Default value: 0

Available values:

0 – auto-off disabled

1-32767 (1s-9.1h, 1s step) – auto-off time

Changing value of this parameter will force the calibration process. During the calibration parameter is set to 1 or 2 and switched to 0 upon completion.

Parameter size: 1B

Default value: 0

Available values:

0 – readout

1 – force auto-calibration without FIBARO Bypass 2

2 – force auto-calibration with FIBARO Bypass 2

This parameter determines operating mode of the device (automatic/manual settings).

Parameter size: 1B

Default value: 0

Available values:

0 – calibration procedure not performed or the device operates on manual settings

1 – the device operates on auto-calibration settings

This parameter defines percentage power variation (compared to power consumption measured during the calibration) to be interpreted as load error/burnt out bulb.

Parameter size: 1B

Default value: 0

Available values:

0 – function disabled

1-99 (1-99%, 1% step) – power variation

This parameter defines detection delay for the burnt out bulb (parameter 161) and overload (parameter 2).

Parameter size: 2B

Default value: 5

Available values:

0 – detection of a burnt out bulb disabled

1-255 (1-255s, 1s step) – time delay

This parameter defines value sent with Switch ON command to devices associated in 2nd and 3rd association group.

Parameter size: 2B

Default value: 255

Available values:

0-99, 255 – value sent

254 – send value equal to the current level

This parameter defines value sent with Switch OFF command to devices associated in 2nd and 3rd association group.

Parameter size: 2B

Default value: 0

Available values:

0-99, 255 – value sent

254 – send value equal to the current level

This parameter defines brightness level set after double-clicking any of the buttons. The same value is also sent to devices associated with 2nd and 3rd association group.

Parameter size: 1B

Default value: 99

Available values:

0-99 (0-99%, 1% step) – set level

This parameter allows to set the desired load control mode. Auto-calibration sets value of this parameter to 2 (control mode recognized during auto-calibration), but the installer may force control mode using this parameter.

After changing parameter value, turn the load OFF and ON to change control mode.

Parameter size: 1B

Default value: 2

Available values:

0 – forced leading edge

1 – forced trailing edge

2 – control mode selected automatically (based on auto-calibration)


(read only)

This parameter allows to read load control mode that was set during auto-calibration.

Parameter size: 1B

Default value: –

Available values:

0 – leading edge

1 – trailing edge

This mode is necessary while connecting non-dimmable light sources. Setting this parameter to 1 automatically ignores brightening/dimming time settings. Forced auto-calibration will set this parameter’s value to 2.

Parameter size: 1B

Default value: 2

Available values:

0 – ON/OFF mode disabled (dimming is possible)

1 – ON/OFF mode enabled (dimming is not possible)

2 – mode selected automatically

This parameter allows to read if the load detected during calibration procedure is dimmable.

Parameter size: 1B

Default value: —

Available values:

0 – load recognized as dimmable

1 – load recognized as non-dimmable

This parameter allows to set time required to warm up the filament of halogen bulb.

Parameter size: 1B

Default value: 1

Available values:

0 – no soft-start

1 – short soft-start (0.1s)

2 – long soft-start (0.5s)

This parameter determines the trigger of auto-calibration procedure, e.g. power on, load error, etc.

Parameter size: 1B

Default value: 1

Available values:

0 – no auto-calibration after power on

2 – Auto-calibration after each power on

3 – Auto-calibration after each LOAD ERROR (no load, load failure, burnt out bulb), if parameter 176 is set to 1 also after SURGE (output overvoltage) and OVERCURRENT (output overcurrent)

4 – Auto-calibration after each power on or after each LOAD ERROR (no load, load failure, burnt out bulb), if parameter 176 is set to 1 also after SURGE (output overvoltage) and OVERCURRENT (output overcurrent)

Error occurrences related to surge or overcurrent results in turning off the output to prevent possible malfunction. By default the device performs three attempts to turn on the load (useful in case of temporary, short failures of the power supply).

Parameter size: 1B

Default value: 1

Available values:

0 – device permanently disabled until re-enabling by command or external switch

1 – three attempts to turn on the load

Correction reduces spontaneous flickering of some capacitive loads (e.g. dimmable LEDs) at certain brightness levels in 2-wire installation.

In countries using ripple-control, correction may cause changes in brightness. In this case it is necessary to disable correction or adjust the time of correction for flickering loads.

Parameter size: 2B

Default value: 255

Available values:

0 – automatic correction disabled

1-254 (1-254s, 1s step) – duration of correction

255 – automatic correction always enabled

This parameter defines how to calculate active power. It is useful in a case of 2-wire connection with light sources other than resistive.

Parameter size: 1B

Default value: 0

Available values:

0 – measurement based on the standard algorithm

1 – approximation based on the calibration data

2 – approximation based on the control angle

This parameter determines the approximate value of the power that will be reported by the device at its maximum brightness level.

Parameter size: 2B

Default value: 0

Available values:

0-500 (0-500W, 1W step) – power consumed by the load at the maximum brightness level.

Back To Top