The remotely operated FIBARO Smart Module and Double Smart Module are designed to turn electrical devices or circuits on and off.
Smart Module (FGS-214) allows to control one device or circuit and the Double Smart Module (FGS-224) allows to control two devices or circuits.
The compact size of the device allows for the product to be installed in the housings of other devices. The devices can be controlled either via the Z-Wave network or with buttons connected directly to them.

Back To Top

Main features

  • Works with various types of switches and buttons.
  • Supports Z-Wave network Security Modes: S0 with AES-128 encryption and S2 Authenticated with PRNG-based encryption.
  • Works as a Z-Wave signal repeater (all non-battery operated devices within the network will act as repeaters to increase reliability of the network).
  • May be used with all devices certified with the Z-Wave Plus certificate and should be compatible with such devices produced by other manufacturers.

The device is a Security Enabled Z-Wave Plus product and a Security Enabled Z-Wave Controller must be used in order to fully utilize the product.

Back To Top

Specifications

Power supply 100-240V~ 50/60Hz or 24-30V DC
Rated load current Smart Module (FGS-214):
6.5A
Double Smart Module (FGS-224):
6A per one channel
9.5A total
Compatible load types resistive or incandescent only
Active element micro-gap relay μ
Maximum length of wires 3 meters
Recommended wire cross-section area 0.2–2.0mm2 (24–14 AWG)
(depending on load current)
Operating temperature 0–35°C
Ambient humidity 0–95% RH without condensation
Radio protocol Z-Wave (500 series chip)
Radio frequency band 868.0–868.6MHz; 869.7–870.0MHz
Max. transmitting power +5dBm
Range up to 50m outdoors
up to 40m indoors
(depending on terrain and building structure
Dimensions
(Height x Width x Depth)
42.5 x 38.25 x 20.3 mm
Classification of installation and use Automatic electrical control for use in equipment for household or similar use
Mode of operation Type 1.C Action
Pollution degree 2
Software class Class A
Protection against electric shock class Class 0
Compliance with EU directives 2011/65/EU
2015/863
2014/53/EU

 

Radio frequency of individual device must be same as your Z-Wave controller. Check information on the box or consult your dealer if you are not sure.

Back To Top

Important safety information

Read this manual before attempting to install the device!

Failure to observe recommendations included in this manual may be dangerous or cause a violation of the law. The manufacturer, Fibar Group S.A. will not be held responsible for any loss or damage resulting from not following the instructions of operating manual.

  • DANGER OF ELECTROCUTION!
    • The device is designed to operate in electrical home installation. Faulty connection or use may result in fire or electric shock.
    • All works on the device may be performed only by a qualified and licensed electrician. Observe national regulations.
    • Even when the device is turned off, voltage may be present at its terminals. Any maintenance introducing changes into the configuration of connections or the load must be always performed with disabled fuse.
    • To avoid risk of electrical shock, do not operate the device with wet or moist hands.
  • Do not modify!
    Do not modify this device in any way not included in this manual.
  • Other devices
    The manufacturer, Fibar Group S.A. will not be held responsible for any damage or loss of warranty privileges for other connected devices if the connection is not compliant with their manuals.
  • This product is intended for indoor use only in dry locations.
    Do not use in damp or wet locations, near a bathtub, sink, shower, swimming pool, or anywhere else where water or moisture are present.
  • Not a toy!
    This product is not a toy. Keep away from children and animals!

Back To Top

Installation

Before installation

Connecting the device in a manner inconsistent with this manual may cause risk to health, life or material damage.

  • Do not power the device before fully assembling it in the protected environment,
  • Check the operating/maintenance manual of the device you want to control to make sure the connection is safe and allowed,
  • Connect only in accordance with the diagram,
  • Always use the same power source for L and IN terminals,
  • Do not connect devices which are not compliant with the specification or relevant safety standards,
  • Do not install the device in metal boxes or on metal surfaces for best radio performance.

Notes for diagrams:
S1 – terminal for 1st button
S2 – terminal for 2nd button
Q/Q1 – output terminal of the 1st channel
Q2 – output terminal of the 2nd channel
IN – input terminal for both channels
L – terminal for live wire
N – terminal for neutral wire
B – maintenance button
1 – device/system housing
2 – electrical device

Back To Top

Electrical connection

  1. Switch off the mains voltage (disable the fuse) or disable the power supply.
  2. Connect with one of the diagrams below:
    Diagram 1: Example connection of Smart Module

    Diagram 2: Example connection of Double Smart Module
  3. Verify correctness of connection.
  4. Tighten the terminal screws using PH1 screwdriver.
  5. If the device fully assembled, switch on the mains voltage or enable the power supply.
  6. The LED light means the device is powered.
  7. Add the device to the Z-Wave network (see the next chapter).

Back To Top

Z-Wave network

Adding to Z-Wave network

Adding (Inclusion) – Z-Wave device learning mode, allowing to add the device to existing Z-Wave network.

Adding manually

To add the device to the Z-Wave network manually:

  1. Power the device.
  2. Set the main controller in (Security/non-Security Mode) add mode (see the controller’s manual).
  3. Quickly, three times click button connected to S1/S2 or the maintenance button.
  4. LED will start blinking yellow, wait for the adding process to end.
  5. If you are adding in Security S2 Authenticated, input the underlined part of the DSK (label on the bottom of the box).
  6. Adding result will be confirmed by the Z-Wave controller’s message and the LED:
    • Green – successful (non-secure, S0, S2 non-authenticated),
    • Magenta – successful (Security S2 Authenticated),
    • Red – not successful.

Adding using SmartStart

SmartStart enabled products can be added into a Z-Wave network by scanning the Z-Wave QR Code present on the product with a controller providing SmartStart inclusion.
SmartStart product will be added automatically within 10 minutes of being switched on in the network range.

To add the device to the Z-Wave network using SmartStart:

  1. To use SmartStart your controller needs to support Security S2 (see the controller’s manual).
  2. Enter the full DSK string code to your controller. If your controller is capable of QR scanning, scan the QR code placed on the box or the device label.
  3. Power the device.
  4. Wait for the adding process to start (up to few minutes), which is signalled with yellow LED blinking.
  5. Adding result will be confirmed by the Z-Wave controller’s message and the LED:
    • Green – successful (non-secure, S0, S2 non-authenticated),
    • Magenta – successful (Security S2 Authenticated),
    • Red – not successful.

In case of problems with adding the device, please reset the device and repeat the adding procedure.

Back To Top

Removing from Z-Wave network

Removing (Exclusion) – Z-Wave device learning mode, allowing to remove the device from existing Z-Wave network. Removing also results in resetting the device to factory defaults.

Make sure that restoring the parameters to factory defaults will not result in damaging the connected device, we recommend disconnecting it first.

To remove the device from the Z-Wave network:

  1. Power the device.
  2. Set the main controller into remove mode (see the controller’s manual).
  3. Quickly, three times click the maintenance button.
  4. LED will start blinking yellow, wait for the removing process to end.
  5. Successful removing will be confirmed by the Z-Wave controller’s message and red LED colour.

Back To Top

Z-Wave range test

The device has a built in Z-Wave network main controller’s range tester.

To make Z-Wave range test possible, the device must be added to the Z-Wave controller. Testing may stress the network, so it is recommended to perform the test only in special cases.

To test the main controller’s range:

  1. Press and hold the maintenance button to enter the menu.
  2. Release button when the device glows magenta.
  3. Quickly click the button to confirm.
  4. Visual indicator will indicate the Z-Wave network’s range (range signaling modes described below).
  5. To exit Z-Wave range test, press the button briefly.

Z-Wave range tester signalling modes:

  • Visual indicator pulsing green – the device attempts to establish a direct communication with the main controller. If a direct communication attempt fails, the device will try to establish a routed communication, through other modules, which will be signalled by visual indicator pulsing yellow.
  • Visual indicator glowing green – the device communicates with the main controller directly.
  • Visual indicator pulsing yellow – the device tries to establish a routed communication with the main controller through other modules (repeaters).
  • Visual indicator glowing yellow – the device communicates with the main controller through the other modules. After 2 seconds the device will retry to establish a direct communication with the main controller, which will be signalled with visual indicator pulsing green.
  • Visual indicator pulsing violet – the device does communicate at the maximum distance of the Z-Wave network. If connection proves successful it will be confirmed with a yellow glow. It’s not recommended to use the device at the range limit.
  • Visual indicator glowing red – the device is not able to connect to the main controller directly or through another Z-Wave network device (repeater).

Communication mode of the device may switch between direct and one using routing, especially if the device is on the limit of the direct range.

Back To Top

Operating the device

Controlling channels with inputs

Momentary switch (parameter 20 set to 0):

1x click – change the state of the channel to the opposite one

Toggle switch without memory (parameter 20 set to 1):

1x switch – change the state of the channel to the state of the switch (OFF if contacts opened, ON if contacts closed)

Toggle switch with memory (parameter 20 set to 2):

1x switch – change the state of the channel to the opposite one

By default S1 input controls 1st channel and S2 input controls 2nd channel if present. It can be changed using parameters 24 and 25.

By default outputs are set as NO (normally open).
It means the contacts will be opened when turned off and closed when turned on. It can be switched to NC (normally closed), which means the contacts will be closed when turned off and opened when turned on using parameters 162/163.

Back To Top

Visual indications

The built-in LED light shows current device status.

After powering the device:

  • Green – device added to a Z-Wave network (non-secure, S0, S2 non-authenticated),
  • Magenta – device added to a Z-Wave network (Security S2 Authenticated),
  • Red – device not added to a Z-Wave network.

Update:

  • Blinking cyan – update in progress,
  • Green – update successful,
  • Red – update not successful.

Menu:

  • Blinking green – entering the menu (added as non-secure, S0, S2 non-authenticated),
  • Blinking magenta – entering the menu (added as Security S2 Authenticated),
  • Blinking red – entering the menu (not added to a Z-Wave network),
  • Magenta – test Z-Wave network range,
  • Yellow – reset to factory defaults.

Back To Top

Menu

Menu allows to perform Z-Wave network actions. In order to use the menu:

  1. Press and hold the maintenance button to enter the menu.
  2. LED will signal adding status for 3 seconds (see Visual indications), then turn off for another 3 seconds.
  3. Release the button when device signals desired position with colour:
    • MAGENTA – test Z-Wave network range
    • YELLOW – reset to factory defaults
  4. Quickly click the button to confirm.

Back To Top

Resetting to factory defaults

Reset procedure allows to restore the device back to its factory settings, which means all information about the Z-Wave controller and user configuration will be deleted.

Make sure that restoring the parameters to factory defaults will not result in damaging the connected device, we recommend disconnecting it first.

Resetting the device is not the recommended way of removing the device from the Z-Wave network. Use reset procedure only if the primary controller is missing or inoperable. Certain device removal can be achieved by the procedure of removing described.

  1. Press and hold the maintenance button to enter the menu.
  2. Release button when the device glows yellow.
  3. Quickly click the button to confirm.
  4. After few seconds the device will be restarted, which is signalled with red LED colour.

Back To Top

Additional features

Activating scenes

The device can activate scenes in the Z-Wave controller by sending scene ID and attribute of a specific action using Central Scene Command Class.

By default all action are activated, change settings of parameters 40 and 41 to disable scene activation for selected actions.

Switch

Action

Scene ID

Attribute

Switch connected to S1 terminal

Switch clicked once

1

Key Pressed 1 time

Switch clicked twice

1

Key Pressed 2 times

Switch clicked thrice*

1

Key Pressed 3 times

Switch held**

1

Key Held Down

Switch released**

1

Key Released

Switch connected to S2 terminal

Switch clicked once

2

Key Pressed 1 time

Switch clicked twice

2

Key Pressed 2 times

Switch clicked thrice*

2

Key Pressed 3 times

Switch held**

2

Key Held Down

Switch released**

2

Key Released

* Activating triple clicks will disallow removing using this input.

** Not available for toggle switches.

Back To Top

Configuration

Advanced parameters

The device allows to customize its operation to user’s needs using configurable parameters.

The settings can be adjusted via Z-Wave controller to which the device is added. The way of adjusting them might differ depending on the controller.

In the FIBARO interface parameters are presented as simple options in Advanced Settings of the device.

Available parameters:

This parameter determines the state of relays after power supply failure (e.g. power outage).

For auto OFF and flashing modes the parameter is not relevant and the relay will always remain switched off.

Parameter size: 1B
Default value: 1 (restore the state)

Available values:

0 – relays remain switched off after restoring power

1 – restore remembered state of relays after restoring power

2 – restore remembered state of relays after restoring power, but for toggle switches (parameter 20/21 set to 1) set the same state as the current state of the switches

This parameter defines as what type the device should treat the switch connected to the S1 terminal.

Parameter size: 1B
Default value: 0 (momentary switch)

Available values:

0 – momentary switch

1 – toggle switch synchronized (contact closed – ON, contact opened – OFF)

2 – toggle switch with memory (device changes status when switch changes status)

This parameter defines as what type the device should treat the switch connected to the S2 terminal.

Parameter size: 1B
Default value: 0 (momentary switch)

Available values:

0 – momentary switch

1 – toggle switch synchronized (contact closed – ON, contact opened – OFF)

2 – toggle switch with memory (device changes status when switch changes status)

This parameter allows reversing operation of S1 and S2 inputs without changing the wiring. Use in case of incorrect wiring.

Parameter size: 1B
Default value: 0 (default)

Available values:

0 – default (S1 – 1st channel, S2 – 2nd channel)

1 – reversed (S1 – 2nd channel, S2 – 1st channel)

Parameter available only in Double Smart Module

This parameter allows reversing operation of Q1 and Q2 outputs without changing the wiring. Use in case of incorrect wiring.

Parameter size: 1B
Default value: 0 (default)

Available values:

0 – default (Q1 – 1st channel, Q2 – 2nd channel)

1 – reversed (Q1 – 2nd channel, Q2 – 1st channel)

This parameter determines to which alarm frames and how the device should react. The parameters consist of 4 bytes, three most significant bytes are set according to the official Z-Wave protocol specification.

Parameter size: 4B
Default value: [0x00, 0x00, 0x00, 0x00] (disabled)

Available values:

1B [MSB] – Notification Type

2B – Notification Status

3B – Event/State Parameters

4B [LSB] – action:

0x00 – no action, 0x01 – turn ON, 0x02 – turn OFF, 0x03 – turn ON/OFF continuously

This parameter determines to which alarm frames and how the device should react. The parameters consist of 4 bytes, three most significant bytes are set according to the official Z-Wave protocol specification.

Parameter size: 4B

Default value: [0x05, 0xFF, 0x00, 0x00]

(Water Alarm, any notification, no action)

Available values:

1B [MSB] – Notification Type

2B – Notification Status

3B – Event/State Parameters

4B [LSB] – action:

0x00 – no action, 0x01 – turn ON, 0x02 – turn OFF, 0x03 – turn ON/OFF continuously

This parameter determines to which alarm frames and how the device should react. The parameters consist of 4 bytes, three most significant bytes are set according to the official Z-Wave protocol specification.

Parameter size: 4B

Default value: [0x01, 0xFF, 0x00, 0x00]

(Smoke Alarm, any notification, no action)

Available values:

1B [MSB] – Notification Type

2B – Notification Status

3B – Event/State Parameters

4B [LSB] – action:

0x00 – no action, 0x01 – turn ON, 0x02 – turn OFF, 0x03 – turn ON/OFF continuously

This parameter determines to which alarm frames and how the device should react. The parameters consist of 4 bytes, three most significant bytes are set according to the official Z-Wave protocol specification.

Parameter size: 4B

Default value: [0x02, 0xFF, 0x00, 0x00]

(CO Alarm, any notification, no action)

Available values:

1B [MSB] – Notification Type

2B – Notification Status

3B – Event/State Parameters

4B [LSB] – action:

0x00 – no action, 0x01 – turn ON, 0x02 – turn OFF, 0x03 – turn ON/OFF continuously

This parameter determines to which alarm frames and how the device should react. The parameters consist of 4 bytes, three most significant bytes are set according to the official Z-Wave protocol specification.

Parameter size: 4B

Default value: [0x04, 0xFF, 0x00, 0x00]

(Heat Alarm, any notification, no action)

Available values:

1B [MSB] – Notification Type

2B – Notification Status

3B – Event/State Parameters

4B [LSB] – action:

0x00 – no action, 0x01 – turn ON, 0x02 – turn OFF, 0x03 – turn ON/OFF continuously

This parameter defines duration of alarm sequence. When time set in this parameter elapses, alarm is cancelled and relays restore normal operation, but do not recover state from before the alarm.

Parameter size: 2B
Default value: 600 (10min)

Available values:

0 – infinite

1-32400 (1s-9h, 1s step) – duration

This parameter determines which actions result in sending scene IDs assigned to them. Values can be combined (e.g. 1+2=3 means that scenes for single and double click are sent).

Enabling scenes for triple click disables entering the device in learning mode by triple clicking.

Parameter size: 1B
Default value: 15 (all active)

Available values:

0 – no scenes sent

1 – Key pressed 1 time

2 – Key pressed 2 times

4 – Key pressed 3 times

8 – Key hold down and key released

This parameter determines which actions result in sending scene IDs assigned to them. Values can be combined (e.g. 1+2=3 means that scenes for single and double click are sent).

Enabling scenes for triple click disables entering the device in learning mode by triple clicking.

Parameter size: 1B
Default value: 15 (all active)

Available values:

0 – no scenes sent

1 – Key pressed 1 time

2 – Key pressed 2 times

4 – Key pressed 3 times

8 – Key hold down and key released

This parameter allows to choose operating mode for channel controlled with Q/Q1 output. For timed modes (value 1, 2 or 3), time is set with parameter 154 and reaction to input change is set with parameter 152.

Parameter size: 1B
Default value: 0 (standard operation)

Available values:

0 – standard operation

1 – delayed OFF

2 – auto OFF

3 – flashing

Parameter available only in Double Smart Module

This parameter allows to choose operating mode for channel controlled with Q2 output. For timed modes (value 1, 2 or 3), time is set with parameter 155 and reaction to input change is set with parameter 153.

Parameter size: 1B
Default value: 0 (standard operation)

Available values:

0 – standard operation

1 – delayed OFF

2 – auto OFF

3 – flashing

This parameter determines how the device reacts when changing state of S1 input in timed modes for first channel.

Parameter size: 1B
Default value: 0 (cancel mode)

Available values:

0 – cancel mode and set default state

1 – no reaction, mode runs until it ends

2 – reset timer, start counting time from the beginning

Parameter available only in Double Smart Module

This parameter determines how the device reacts when changing state of S2 input in timed modes for second channel.

Parameter size: 1B
Default value: 0 (cancel mode)

Available values:

0 – cancel mode and set default state

1 – no reaction, mode runs until it ends

2 – reset timer, start counting time from the beginning

This parameter allows to set time parameter used in timed modes for first channel. For delayed/auto OFF modes it determines duration, for flashing mode it determines cycle period.

Parameter size: 2B
Default value: 5 (0.5s)

Available values:

0 – 0.1 seconds

1-32000 – 0.1-3200 seconds, 0.1s step

Parameter available only in Double Smart Module

This parameter allows to set time parameter used in timed modes for second channel. For delayed/auto OFF modes it determines duration, for flashing mode it determines cycle period.

Parameter size: 2B
Default value: 5 (0.5s)

Available values:

0 – 0.1 seconds

1-32000 – 0.1-3200 seconds, 0.1s step

This parameter defines value sent with Switch ON command to devices in 2nd association group when using S1 input.

Parameter size: 2B
Default value: 255

Available values:

0 – turn off
1-99 – turn on and set level
255 – turn on with last level

This parameter defines value sent with Switch OFF command to devices in 2nd association group when using S1 input.

Parameter size: 2B
Default value: 0

Available values:

0 – turn off
1-99 – turn on and set level
255 – turn on with last level

This parameter defines value sent with Double Click command to devices in 2nd association group when using S1 input.

Parameter size: 2B
Default value: 99

Available values:

0 – turn off
1-99 – turn on and set level
255 – turn on with last level

Parameter available only in Double Smart Module

This parameter defines value sent with Switch ON command to devices in 3rd association group when using S2 input.

Parameter size: 2B
Default value: 255

Available values:

0 – turn off
1-99 – turn on and set level
255 – turn on with last level

Parameter available only in Double Smart Module

This parameter defines value sent with Switch OFF command to devices in 3rd association group when using S2 input.

Parameter size: 2B
Default value: 0

Available values:

0 – turn off
1-99 – turn on and set level
255 – turn on with last level

Parameter available only in Double Smart Module

This parameter defines value sent with Double Click command to devices in 3rd association group when using S2 input.

Parameter size: 2B
Default value: 99

Available values:

0 – turn off
1-99 – turn on and set level
255 – turn on with last level

This parameter determines type of Q/Q1 output.

Parameter size: 1B
Default value: 0 (Normally Open)

Available values:

0 – Normally Open (relay contacts opened turned off, closed when turned on)

1 – Normally Closed (relay contacts closed turned off, opened when turned on)

Parameter available only in Double Smart Module

This parameter determines type of Q2 output.

Parameter size: 1B
Default value: 0 (Normally Open)

Available values:

0 – Normally Open (relay contacts opened turned off, closed when turned on)

1 – Normally Closed (relay contacts closed turned off, opened when turned on)

Parameter available only in Double Smart Module

When the lock is enabled, both outputs cannot be turned on at the same time.

Parameter size: 1B
Default value: 0 (lock disabled)

Available values:

0 – lock disabled

1 – lock enabled

Back To Top