- Rooms with one heater. FG(BH)T-001 is installed in all rooms.
- Each room is controlled independently.
- It is possible to use the FGBRS-001 sensor if we want to improve the quality of the regulation.
- Each room is controlled from the FIBARO system.
- Rooms with one heater. FG(BH)T is not installed in all rooms.
- FG(BH)T-001 is installed where you want to intelligently control the temperature.
- It is possible to use the FGBRS-001 sensor if we want to improve the quality of the regulation (only rooms with FG(BH)T-001).
- Not every room is controlled from the FIBARO system.
- Rooms with more than one heater (2-3 heaters). FG(BH)T-001 is installed on all heaters.
- All FG(BH)T-001 sensors located in one room should have the same schedule (be in the same heating zone).
- It is recommended to use only one FGBRS-001 sensor in the room.
- The FGBRS-001 sensor (if used) should be paired with all heads in the room in which it is located.
- The FGBRS-001 sensor can be paired with up to three FG(BH)T-001 heads.
- Rooms with more than one heater (2-3 heaters). FG(BH)T-001 is not installed on all heaters.
- It is recommended that heaters that do not have FG(BH)T-001 head have a valve set in the anti-frost mode so they do not affect the operation of FG(BH)T-001.
- Rooms with more than 3 heaters. FG(BH)T-001 is installed on all heaters or FG(BH)T-001 is not installed on all heaters, but there are more than 3 heaters in the room.
- All FG(BH)T-001 sensors located in one room should have the same schedule (be in the same heating zone).
- It is not recommended to use the FGBRS-001 sensor, as it may be exposed to heat not coming from the radiator, which is controlled by the head unpaired with this sensor.
- If the FGBRS-001 sensor will be used you have to make sure that it is paired with FG(BH)T-001 heads whose heaters influence the temperature in the room.
- It is recommended that heaters that do not have FG(BH)T-001 head have a valve set in the anti-frost mode so they do not affect the operation of FG(BH)T-001.
- The central thermostat controls the operation of the furnace. FG(BH)T-001 is installed on radiators other than the one in which the wall thermostat works.
- FG(BH)T-001 should work only in OFF / FULL ON mode. Their only function is to turn off the heating in rooms that are used sporadically.
- In the case of FG(BH)T-001 work, in such a configuration, using the schedule, the quality of regulation will be significantly reduced (temporary overheating or unheated rooms or lack of possibility to heat the room).
- The central thermostat controls the operation of the furnace. FG(BH)T-001 installed on all heaters, also on the heater located in the room in which the wall thermostat works.
- This isn’t the recommended operating mode, because FG(BH)T-001 placed in one room with a wall thermostat will affect its operation and vice versa.
- The FGBRS-001 sensor isn’t placed in the same room as FG(BH)T-001 paired with this sensor.
- This isn’t the recommended operating mode because the temperature regulation point (FGBRS-001 sensor) is located outside the operating range of the heater controlled by FG(BH)T-001.