FIBARO Roller Shutter 2 can send Scene ID to trigger scenes in the controller.
Different actions with switches connected to the Roller Shutter 2 will result in sending different IDs.
Change parameter 50 to 1 in order to enable Scene Activation functionality.
SCENE ID value sent at specified configuration:
Momentary switches (parameter 14 = 0, parameter 10 = 0,1,2) | |
---|---|
SCENE ID: S1 input | SCENE ID: S2 input |
12 : hold 13 : release 14 : 2 x click 16 : 1 x click |
22 : hold 23 : release 24 : 2 x click 25 : 3 x click 26 : 1 x click |
Toggle switches (parameter 14 = 1, parameter 10 = 0,1,2) | |
SCENE ID: S1 input | SCENE ID: S2 input |
10 : OFF to ON 11 : ON to OFF 14 : 2 x click |
20 : OFF to ON 21 : ON to OFF 24 : 2 x click 25 : 3 x click |
Momentary switch (parameter 14 = 2, parameter 10 = 0,1,2) | |
SCENE ID: S1 input | SCENE ID: S2 input |
12 : hold 13 : release 14 : 2 x click 16 : 1 x click |
S2 input disabled due to the parameters configuration. |
Switch for gate (parameter 10 = 3,4) | |
SCENE ID: S1 input | SCENE ID: S2 input |
12 : hold 13 : release 14 : 2 x click 16 : 1 x click |
S2 input disabled due to the parameters configuration |