FIBARO Roller Shutter 2 can send Scene ID to trigger scenes in the controller.
Different actions with switches connected to the Roller Shutter 2 will result in sending different IDs.
Change parameter 50 to 1 in order to enable Scene Activation functionality.

SCENE ID value sent at specified configuration:

Momentary switches (parameter 14 = 0, parameter 10 = 0,1,2)
SCENE ID: S1 input SCENE ID: S2 input
12 : hold
13 : release
14 : 2 x click
16 : 1 x click
22 : hold
23 : release
24 : 2 x click
25 : 3 x click
26 : 1 x click
Toggle switches (parameter 14 = 1, parameter 10 = 0,1,2)
SCENE ID: S1 input SCENE ID: S2 input
10 : OFF to ON
11 : ON to OFF
14 : 2 x click
20 : OFF to ON
21 : ON to OFF
24 : 2 x click
25 : 3 x click
Momentary switch (parameter 14 = 2, parameter 10 = 0,1,2)
SCENE ID: S1 input SCENE ID: S2 input
12 : hold
13 : release
14 : 2 x click
16 : 1 x click
S2 input disabled due to the parameters configuration.
Switch for gate (parameter 10 = 3,4)
SCENE ID: S1 input SCENE ID: S2 input
12 : hold
13 : release
14 : 2 x click
16 : 1 x click
S2 input disabled due to the parameters configuration