The device allows to customize its operation to user’s needs using configurable parameters.

The settings can be adjusted via Z-Wave controller to which the device is added. The way of adjusting them might differ depending on the controller.

In the FIBARO interface parameters are presented as simple options in Advanced Settings of the device.

Available parameters:

This parameter determines how the device will react in the event of power supply failure (e.g. power outage).

Parameter size: 1B

Default value: 1 (restores the state)

Available values:

0 – remains switched off after restoring power

1 – restores remembered state after restoring power

This function allows to turn off the controlled device in case of exceeding the defined power. Controlled device can be turned back on via the button or sending a control frame.

Parameter size: 4B

Default value: 3500 (350W)

Available values:

0 – function disabled

10-5000 (1.0-500.0W, step 0.1W) – power threshold

This parameter determines maximum active power. Exceeding it results in the LED frame flashing violet. Function is active only when parameter 11 is set to 8 or 9.

Parameter size: 4B

Default value: 3500 (350W)

Available values:

100-5000 (10.0-500.0W, step 0.1W) – power threshold

This parameter defines the LED colour when the device is ON.

When set to 8 or 9, LED frame colour will change depending on the measured power and parameter 10. Other colours are set permanently and do not depend on power consumption.

Parameter size: 1B

Default value: 1 (white)

Available values:

0 – LED disabled

1 – White

2 – Red

3 – Green

4 – Blue

5 – Yellow

6 – Cyan

7 – Magenta

8 – colour changes in steps depending on measured power

9 – colour changes in steps depending on measured power

This parameter defines the LED colour when the device is OFF.

Parameter size: 1B

Default value: 0 (disabled)

Available values:

0 – LED disabled

1 – White

2 – Red

3 – Green

4 – Blue

5 – Yellow

6 – Cyan

7 – Magenta

This parameter allows to adjust the LED frame brightness.

Parameter size: 1B

Default value: 100 (100%)

Available values:

0 – LED disabled

1-100 (1-100% brightness)

101 – brightness directly proportional to set level

102 – brightness inversely proportional to set level

This parameter allows reversing the operation of the buttons.

Parameter size: 1B

Default value: 0

Available values:

0 – default (1st button brightens, 2nd button dims)

1 – reversed (1st button dims, 2nd button brightens)

This parameter determines to which alarm frames and how the device should react. The parameters consist of 4 bytes, three most significant bytes are set according to the official Z-Wave protocol specification.

Parameter size: 4B

Default value: [0x00, 0x00, 0x00, 0x00] (disabled)

Available values:

1B [MSB] – Notification Type

2B – Notification Status

3B – Event/State Parameters

4B [LSB] – action:

0x00 – no action,
0xX1 – turn ON,
0xX2 – turn OFF,
0xX3 – turn ON/OFF continuously,
0x0X – no action on LED frame,
0x1X – LED frame blinks red,
0x2X – LED frame blinks green,
0x4X – LED frame blinks blue,
0x8X – disable LED frame,
0xFX – LED frame LAPD signal (red-white-blue)

This parameter determines to which alarm frames and how the device should react. The parameters consist of 4 bytes, three most significant bytes are set according to the official Z-Wave protocol specification.

Parameter size: 4B

Default value

[0x05, 0xFF, 0x00, 0x00]

(Water Alarm, any notification, no action)

Available values:

1B [MSB] – Notification Type

2B – Notification Status

3B – Event/State Parameters

4B [LSB] – action:

0x00 – no action,
0xX1 – turn ON,
0xX2 – turn OFF,
0xX3 – turn ON/OFF continuously,
0x0X – no action on LED frame,
0x1X – LED frame blinks red,
0x2X – LED frame blinks green,
0x4X – LED frame blinks blue,
0x8X – disable LED frame,
0xFX – LED frame LAPD signal (red-white-blue)

This parameter determines to which alarm frames and how the device should react. The parameters consist of 4 bytes, three most significant bytes are set according to the official Z-Wave protocol specification.

Parameter size: 4B

Default value

[0x01, 0xFF, 0x00, 0x00]

(Smoke Alarm, any notification, no action)

Available values:

1B [MSB] – Notification Type

2B – Notification Status

3B – Event/State Parameters

4B [LSB] – action:

0x00 – no action,
0xX1 – turn ON,
0xX2 – turn OFF,
0xX3 – turn ON/OFF continuously,
0x0X – no action on LED frame,
0x1X – LED frame blinks red,
0x2X – LED frame blinks green,
0x4X – LED frame blinks blue,
0x8X – disable LED frame,
0xFX – LED frame LAPD signal (red-white-blue)

This parameter determines to which alarm frames and how the device should react. The parameters consist of 4 bytes, three most significant bytes are set according to the official Z-Wave protocol specification.

Parameter size: 4B

Default value

[0x02, 0xFF, 0x00, 0x00]

(CO Alarm, any notification, no action)

Available values:

1B [MSB] – Notification Type

2B – Notification Status

3B – Event/State Parameters

4B [LSB] – action:

0x00 – no action,
0xX1 – turn ON,
0xX2 – turn OFF,
0xX3 – turn ON/OFF continuously,
0x0X – no action on LED frame,
0x1X – LED frame blinks red,
0x2X – LED frame blinks green,
0x4X – LED frame blinks blue,
0x8X – disable LED frame,
0xFX – LED frame LAPD signal (red-white-blue)

This parameter determines to which alarm frames and how the device should react. The parameters consist of 4 bytes, three most significant bytes are set according to the official Z-Wave protocol specification.

Parameter size: 4B

Default value

[0x04, 0xFF, 0x00, 0x00]

(Heat Alarm, any notification, no action)

Available values:

1B [MSB] – Notification Type

2B – Notification Status

3B – Event/State Parameters

4B [LSB] – action:

0x00 – no action,
0xX1 – turn ON,
0xX2 – turn OFF,
0xX3 – turn ON/OFF continuously,
0x0X – no action on LED frame,
0x1X – LED frame blinks red,
0x2X – LED frame blinks green,
0x4X – LED frame blinks blue,
0x8X – disable LED frame,
0xFX – LED frame LAPD signal (red-white-blue)

This parameter defines duration of alarm sequence. When time set in this parameter elapses, alarm is cancelled, LED frame and relay restore normal operation, but do not recover state from before the alarm.

Parameter size: 2B

Default value: 600 (10min)

Available values:

0 – infinite

1-32400 (1s-9h, 1s step) – duration

This parameter determines which actions result in sending scene IDs assigned to them. Values can be combined (e.g. 1+2=3 means that scenes for single and double click are sent).

Enabling scenes for triple click disables entering the device in learn mode by triple clicking.

Parameter size: 1B

Default value: 0 (no scenes)

Available values:

1 – Key pressed 1 time

2 – Key pressed 2 times

4 – Key pressed 3 times

8 – Key hold down and key released

This parameter determines which actions result in sending scene IDs assigned to them. Values can be combined (e.g. 1+2=3 means that scenes for single and double click are sent).

Enabling scenes for triple click disables entering the device in learn mode by triple clicking.

Parameter size: 1B

Default value: 0 (no scenes)

Available values:

1 – Key pressed 1 time

2 – Key pressed 2 times

4 – Key pressed 3 times

8 – Key hold down and key released

This parameter determines whether the power measurements should include power consumed by the device itself.

Parameter size: 1B

Default value: 0 (not included)

Available values:

0 – Self-consumption not included

1 – Self-consumption included

This parameter defines minimal change (from the last reported) in measured power that results in sending new report. For loads under 50W the parameter is irrelevant, report are sent every 5W change.

Parameter size: 2B

Default value: 15 (15%)

Available values:

0 – reporting on change disabled

1-500 (1-500%, 1% step) – minimal change

This parameter defines reporting interval for measured power. Periodic reports are independent from changes in value (parameter 61).

Parameter size: 2B

Default value: 3600 (1h)

Available values:

0 – periodic reports disabled

30-32400 (30s-9h, 1s step) – time interval

This parameter defines minimal change (from the last reported) in measured energy that results in sending new report.

Parameter size: 2B

Default value: 10 (0.1kWh)

Available values:

0 – reporting on change disabled

1-500 (0.01-5kWh, 0.01kWh step) – minimal change

This parameter defines reporting interval for measured energy. Periodic reports are independent from changes in value (parameter 65).

Parameter size: 2B

Default value: 3600 (1h)

Available values:

0 – periodic reports disabled

30-32400 (30s-9h, 1s step) – time interval

This parameter is set automatically during the calibration process, but can be changed manually after the calibration.

Parameter size: 1B

Default value: 1

Available values:

1-98 (1-98%, 1% step) – level of brightness

This parameter is set automatically during the calibration process, but can be changed manually after the calibration.

Parameter size: 1B

Default value: 99

Available values:

2-99 (2-99%, 1% step) – level of brightness

The virtual value set as a percentage level between parameters MIN (1%) and MAX. (99%). The device will set to this value after the first switch on. It is required for warming up and switching dimmable compact fluorescent lamps and certain types of light sources.

Parameter size: 1B

Default value: 1

Available values:

1-99 (1-98%, 1% step) – level of brightness

This parameter determines the time required for switching compact fluorescent lamps and certain types of light sources. Setting this parameter to 0 will disable the incandescence functionality.

Parameter size: 2B

Default value: 0

Available values:

0-255 (0-25.5s, 0.1s step) – incandescence time

This parameter defines the percentage value of dimming step during the automatic control.

Parameter size: 1B

Default value: 1

Available values:

1-99 (1-99%, 1% step) – dimming step

This parameter defines the time of performing a single dimming step set in parameter 154 during the automatic control.

Parameter size: 2B

Default value: 1 (10ms)

Available values:

0-255 (0-2.55s, 10ms step)

This parameter defines the percentage value of the dimming step during the manual control.

Parameter size: 1B

Default value: 1

Available values:

1-99 (1-99%, 1% step) – dimming step

This parameter defines the time of performing a single dimming step set in parameter 156 during the manual control.

Parameter size: 2B

Default value: 5 (50ms)

Available values:

0-255 (0-2.55s, 10ms step)

This parameter allows to automatically switch off the device after a specified time from switching the light source on. It may be useful when the device is installed in the stairway.

Parameter size: 2B

Default value: 0

Available values:

0 – auto-off disabled

1-32767 (1s-9.1h, 1s step) – auto-off time

Changing value of this parameter will force the calibration process. During the calibration parameter is set to 1 or 2 and switched to 0 upon completion.

Parameter size: 1B

Default value: 0

Available values:

0 – readout

1 – force auto-calibration without FIBARO Bypass 2

2 – force auto-calibration with FIBARO Bypass 2

This parameter determines operating mode of the device (automatic/manual settings).

Parameter size: 1B

Default value: 0

Available values:

0 – calibration procedure not performed or the device operates on manual settings

1 – the device operates on auto-calibration settings

This parameter defines percentage power variation (compared to power consumption measured during the calibration) to be interpreted as load error/burnt out bulb.

Parameter size: 1B

Default value: 0

Available values:

0 – function disabled

1-99 (1-99%, 1% step) – power variation

This parameter defines detection delay for the burnt out bulb (parameter 161) and overload (parameter 2).

Parameter size: 2B

Default value: 5

Available values:

0 – detection of a burnt out bulb disabled

1-255 (1-255s, 1s step) – time delay

This parameter defines value sent with Switch ON command to devices associated in 2nd and 3rd association group.

Parameter size: 2B

Default value: 255

Available values:

0-99, 255 – value sent

254 – send value equal to the current level

This parameter defines value sent with Switch OFF command to devices associated in 2nd and 3rd association group.

Parameter size: 2B

Default value: 0

Available values:

0-99, 255 – value sent

254 – send value equal to the current level

This parameter defines brightness level set after double-clicking any of the buttons. The same value is also sent to devices associated with 2nd and 3rd association group.

Parameter size: 1B

Default value: 99

Available values:

0-99 (0-99%, 1% step) – set level

This parameter allows to set the desired load control mode. Auto-calibration sets value of this parameter to 2 (control mode recognized during auto-calibration), but the installer may force control mode using this parameter.

After changing parameter value, turn the load OFF and ON to change control mode.

Parameter size: 1B

Default value: 2

Available values:

0 – forced leading edge

1 – forced trailing edge

2 – control mode selected automatically (based on auto-calibration)


(read only)

This parameter allows to read load control mode that was set during auto-calibration.

Parameter size: 1B

Default value: –

Available values:

0 – leading edge

1 – trailing edge

This mode is necessary while connecting non-dimmable light sources. Setting this parameter to 1 automatically ignores brightening/dimming time settings. Forced auto-calibration will set this parameter’s value to 2.

Parameter size: 1B

Default value: 2

Available values:

0 – ON/OFF mode disabled (dimming is possible)

1 – ON/OFF mode enabled (dimming is not possible)

2 – mode selected automatically

This parameter allows to read if the load detected during calibration procedure is dimmable.

Parameter size: 1B

Default value: —

Available values:

0 – load recognized as dimmable

1 – load recognized as non-dimmable

This parameter allows to set time required to warm up the filament of halogen bulb.

Parameter size: 1B

Default value: 1

Available values:

0 – no soft-start

1 – short soft-start (0.1s)

2 – long soft-start (0.5s)

This parameter determines the trigger of auto-calibration procedure, e.g. power on, load error, etc.

Parameter size: 1B

Default value: 1

Available values:

0 – no auto-calibration after power on

2 – Auto-calibration after each power on

3 – Auto-calibration after each LOAD ERROR (no load, load failure, burnt out bulb), if parameter 176 is set to 1 also after SURGE (output overvoltage) and OVERCURRENT (output overcurrent)

4 – Auto-calibration after each power on or after each LOAD ERROR (no load, load failure, burnt out bulb), if parameter 176 is set to 1 also after SURGE (output overvoltage) and OVERCURRENT (output overcurrent)

Error occurrences related to surge or overcurrent results in turning off the output to prevent possible malfunction. By default the device performs three attempts to turn on the load (useful in case of temporary, short failures of the power supply).

Parameter size: 1B

Default value: 1

Available values:

0 – device permanently disabled until re-enabling by command or external switch

1 – three attempts to turn on the load

Correction reduces spontaneous flickering of some capacitive loads (e.g. dimmable LEDs) at certain brightness levels in 2-wire installation.

In countries using ripple-control, correction may cause changes in brightness. In this case it is necessary to disable correction or adjust the time of correction for flickering loads.

Parameter size: 2B

Default value: 255

Available values:

0 – automatic correction disabled

1-254 (1-254s, 1s step) – duration of correction

255 – automatic correction always enabled

This parameter defines how to calculate active power. It is useful in a case of 2-wire connection with light sources other than resistive.

Parameter size: 1B

Default value: 0

Available values:

0 – measurement based on the standard algorithm

1 – approximation based on the calibration data

2 – approximation based on the control angle

This parameter determines the approximate value of the power that will be reported by the device at its maximum brightness level.

Parameter size: 2B

Default value: 0

Available values:

0-500 (0-500W, 1W step) – power consumed by the load at the maximum brightness level.